Graco 312877C Mounting, Grounding, Fluid supply container Follow local code

Page 7

Mounting

The pump exhaust air may contain contam- inants. Ventilate to a remote area. See Air Exhaust Ventilation on page 8.

Never move or lift a pump under pressure. If dropped, the fluid section may rupture. Always follow the Pressure Relief Proce- dure on page 14 before moving or lifting the pump.

1.Be sure the mounting surface can support the weight of the pump, hoses, and acces- sories, as well as the stress caused during operation.

2.For all mountings, be sure the pump is bolted directly to the mounting surface.

3.For ease of operation and service, mount the pump so air valve, air inlet, fluid inlet and fluid outlet ports are easily accessible.

4.Rubber Foot Mounting Kit 236452 is avail- able to reduce noise and vibration during operation.

Grounding

Installation

wire to a true earth ground. A ground wire and clamp, Part 238909, is available from Graco.

Polypropylene: Only conductive polypropyl- ene pumps have a ground screw. Standard polypropylene pumps are not conductive. Never use a non-conductive polypropylene pump with non-conductive flammable fluids. Follow your local fire codes. When pumping conductive flammable fluids, always ground the entire fluid system as described.

GS

R

ti12214a

FIG. 1. Grounding screw and wire

Air and fluid hoses: Use only grounded hoses with a maximum of 500 ft (150 m) com- bined hose length to ensure grounding conti- nuity.

Air compressor: Follow manufacturer’s recommendations.

The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical cur- rent due to static build up or in the event of a short circuit.

Pump: See FIG. 1. Loosen the grounding screw (GS). Insert one end of a 12 ga. minimum ground wire (R) behind the grounding screw and tighten the screw securely. Connect the clamp end of the ground

Fluid supply container: Follow local code.

Solvent pails used when flushing: Follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts ground- ing continuity.

312877C

7

Image 7
Contents 1050S Stainless Steel Important Safety Instructions1050P Polypropylene 1050C Conductive 1050A AluminumRelated Manuals ContentsAtex Certifications Pump MatrixFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Tighten Fasteners Before Setup InstallationGrounding MountingFluid supply container Follow local code Air Line Reed SwitchAir Exhaust Ventilation Fluid Outlet Line Fluid Supply LineKey Typical bung-mount installation aluminum, 1050A, pump shown C BA Bolt tightening sequence Fluid Inlet and Outlet PortsAluminum 1050A Stainless Steel 1050SFluid pressure relief kit Aluminum pumps only, 1050A models Fluid Pressure Relief ValveOperation Pressure Relief Procedure Starting and Adjusting the PumpFlush the Pump Before First Use Maintenance Torque sequence Torque Instructions312877C Aluminum 1050A Dimensions and MountingNptf air inlet Polypropylene 1050P and Conductive Polypropylene 1050CIn. ANSI/DIN flange Stainless Steel 1050S Fluid Pressure Performance ChartsAir Consumption Technical Data Stainless Steel Pumps Fluid Temperature RangeFluid Temperature Range Aluminum orGraco Information Graco Standard Husky Pump Warranty