Graco 312877C important safety instructions Fire and Explosion Hazard

Page 4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equip- ment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable materials and gases. To help prevent fire and explosion:

Clean plastic parts in a well ventilated area.

Do not clean with a dry cloth.

4

312877C

Image 4
Contents Important Safety Instructions 1050P Polypropylene 1050C Conductive1050A Aluminum 1050S Stainless SteelContents Related ManualsPump Matrix Atex CertificationsFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Installation Tighten Fasteners Before SetupGrounding MountingFluid supply container Follow local code Air Line Reed SwitchAir Exhaust Ventilation Fluid Outlet Line Fluid Supply LineKey Typical bung-mount installation aluminum, 1050A, pump shown C BA Fluid Inlet and Outlet Ports Aluminum 1050AStainless Steel 1050S Bolt tightening sequenceFluid Pressure Relief Valve Fluid pressure relief kit Aluminum pumps only, 1050A modelsOperation Pressure Relief Procedure Starting and Adjusting the PumpFlush the Pump Before First Use Maintenance Torque Instructions Torque sequence312877C Dimensions and Mounting Aluminum 1050ANptf air inlet Polypropylene 1050P and Conductive Polypropylene 1050CIn. ANSI/DIN flange Stainless Steel 1050S Fluid Pressure Performance ChartsAir Consumption Technical Data Fluid Temperature Range Fluid Temperature RangeAluminum or Stainless Steel PumpsGraco Standard Husky Pump Warranty Graco Information