Graco 312877C important safety instructions C Ba

Page 11

Installation

E F C BA

N

D

R

K L

J

G

M

ti14164a

FIG. 4. Typical floor-mount installation (polypropylene, 1050P, pump shown)

Key for FIG. 3 and FIG. 4:

AAir supply line

BBleed-type master air valve (required for pump)

CAir regulator

DAir inlet

EMaster air valve (for accessories)

FAir line filter

GFluid suction line

HBung adapter

JFluid drain valve (required)

KFluid shutoff valve

LFluid line

MFluid inlet (Aluminum, FIG. 3, four ports, one not visible; Plastic, FIG. 4, center or end flanges available; Stainless Steel, not pictured, one port)

NFluid outlet (Aluminum, FIG. 3, four ports, one not visible; Plastic, FIG. 4, center or end flanges available; Stainless Steel, not pictured, one

port)

RGround wire (required for aluminum, conductive polypropylene, and stainless steel pumps; see page 7 for installation instructions)

312877C

11

Image 11
Contents 1050S Stainless Steel Important Safety Instructions1050P Polypropylene 1050C Conductive 1050A AluminumRelated Manuals ContentsAtex Certifications Pump MatrixFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Tighten Fasteners Before Setup InstallationFluid supply container Follow local code MountingGrounding Air Exhaust Ventilation Reed SwitchAir Line Key Fluid Supply LineFluid Outlet Line Typical bung-mount installation aluminum, 1050A, pump shown C BA Bolt tightening sequence Fluid Inlet and Outlet PortsAluminum 1050A Stainless Steel 1050SFluid pressure relief kit Aluminum pumps only, 1050A models Fluid Pressure Relief ValveFlush the Pump Before First Use Pressure Relief Procedure Starting and Adjusting the PumpOperation Maintenance Torque sequence Torque Instructions312877C Aluminum 1050A Dimensions and MountingIn. ANSI/DIN flange Polypropylene 1050P and Conductive Polypropylene 1050CNptf air inlet Stainless Steel 1050S Air Consumption Performance ChartsFluid Pressure Technical Data Stainless Steel Pumps Fluid Temperature RangeFluid Temperature Range Aluminum orGraco Information Graco Standard Husky Pump Warranty