Graco 312877C Operation, Pressure Relief Procedure Starting and Adjusting the Pump

Page 14

Operation

Operation

Pressure Relief Procedure

Starting and Adjusting the Pump

Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing.

1.Shut off the air supply to the pump.

2.Open the dispensing valve, if used.

3.Open the fluid drain valve to relieve fluid pressure. Have a container ready to catch the drainage.

Flush the Pump Before First Use

The pump was tested in water. If water could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing and Storage, page 15.

Tighten Fasteners Before Setup

Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16. After the first day of operation, retorque the fasteners.

1.Be sure the pump is properly grounded. Refer to Grounding on page 7.

2.Check fittings to be sure they are tight. Use a compatible liquid thread sealant on male threads. Tighten fluid inlet and outlet fittings securely.

3.Place the suction tube (if used) in fluid to be pumped.

NOTE: If fluid inlet pressure to the pump is more than 25% of outlet working pressure, the ball check valves will not close fast enough, resulting in inefficient pump operation.

4.Place the end of the fluid hose into an appropriate container.

5.Close the fluid drain valve.

6.Back out the air regulator knob, and open all bleed-type master air valves.

7.If the fluid hose has a dispensing device, hold it open.

8.Pumps with runaway protection: Enable the prime/flush function by pushing the prime/flush button on the DataTrak.

9.Slowly increase air pressure with the air regulator until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed.

14

312877C

Image 14
Contents 1050A Aluminum Important Safety Instructions1050P Polypropylene 1050C Conductive 1050S Stainless SteelContents Related ManualsPump Matrix Atex CertificationsFire and Explosion Hazard Plastic Parts Cleaning Solvent Hazard Installation Tighten Fasteners Before SetupFluid supply container Follow local code MountingGrounding Air Exhaust Ventilation Reed SwitchAir Line Key Fluid Supply LineFluid Outlet Line Typical bung-mount installation aluminum, 1050A, pump shown C BA Stainless Steel 1050S Fluid Inlet and Outlet PortsAluminum 1050A Bolt tightening sequenceFluid Pressure Relief Valve Fluid pressure relief kit Aluminum pumps only, 1050A modelsFlush the Pump Before First Use Pressure Relief Procedure Starting and Adjusting the PumpOperation Maintenance Torque Instructions Torque sequence312877C Dimensions and Mounting Aluminum 1050AIn. ANSI/DIN flange Polypropylene 1050P and Conductive Polypropylene 1050CNptf air inlet Stainless Steel 1050S Air Consumption Performance ChartsFluid Pressure Technical Data Aluminum or Fluid Temperature RangeFluid Temperature Range Stainless Steel PumpsGraco Standard Husky Pump Warranty Graco Information