Technical Data
3:1 Ratio President Pumps, Models
Maximum Working Pressure | 3.4 MPa, 34 bar (500 psi) | Wetted Parts |
|
Air Operating Range . | Model | . Carbon Steel, Stainless Steel, | |
Air Consumption | . See Performance Chart | ||
Continuous Duty Delivery | . 35.3 liter/min (9.3 gpm) | Model | |
Pump Cycles Per Liter (gallon) . . . . | . . . . . . . . . . . . . 1.7 (6.25) | ||
Maximum Recommended Pump Speed . . . . . 60 cycles/min | Model | . Carbon Steel, Stainless Steel, | |
Air Inlet | . . . . . . . . . . . . . 1/2 npt(f) | ||
Fluid Inlet | . . . . . . . . . . . | Model | |
Fluid Outlet | . . . . . . . . . . . . . . . . 1” npt |
| MPa, BAR PSI |
|
|
| CPM |
|
|
|
|
|
| ||
|
| 12 | 25 | 37 | 50 | 62 | 74 | 87 |
|
|
| ||
| 2.8, 28 | 400 |
|
| m3/min | ||||||||
|
|
|
|
|
|
|
| CFM | |||||
| 2.45, 24.5 | 350 |
|
|
|
|
|
|
|
| 70 | 1.96 |
|
PUMP OUTLET PRESSURE | 2.1, 21 | 300 |
| A |
|
|
|
|
|
| 60 | 1.68 | AIR CONSUMPTION |
1.7, 17 | 250 |
|
|
|
|
|
|
| 50 | 1.40 | |||
|
|
|
|
|
|
| A | ||||||
1.4, 14 | 200 |
| B |
|
|
|
|
| 40 | 1.12 | |||
|
|
|
|
|
|
| |||||||
| 150 |
|
|
|
|
|
| B |
|
| |||
1.05, 10.5 |
|
|
|
|
|
|
| 30 | 0.84 | ||||
| C |
|
|
| C |
|
| ||||||
0.7, 7 | 100 |
|
|
|
|
|
| 20 | 0.56 | ||||
0.35, 3.5 | 50 |
|
|
|
|
|
|
|
| 10 | 0.28 | ||
|
|
|
|
|
|
|
|
|
| ||||
|
| 0 | 0 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 0 |
|
|
| GPM |
|
| ||||||||||
| l/min |
| 8 | 15 | 23 | 30 | 38 | 46 | 54 |
|
|
|
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
A0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure
To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):
1.Locate desired delivery along bottom of chart.
2.Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.
To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):
1.Locate desired delivery along bottom of chart.
2.Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.
789 41