Viscount I+ Pumps, Models 236–712 and 236–713

Technical Data

Viscount I+ Pumps, Models 236–712 and 236–713

Maximum Working Pressure . .

1.55 MPa, 15.5 bar (225 psi)

Wetted Parts

 

Maximum Hydraulic Working Pressure . . 10.3 MPa, 103 bar

Model 236–712

. Carbon Steel, Stainless Steel,

 

 

(1500 psi)

Ultra-High Molecular Weight Polyethylene, Leather, PTFE r

Continuous Duty Delivery

. . . . . 75.6 liter/min (20 gpm)

Model 236–713

Chrome-Plated Stainless Steel,

Pump Cycles Per Liter (gallon) .

. . . . . . . . . . . .

. . . . . 0.8 (3.0)

Ultra-High Molecular Weight Polyethylene, Leather, PTFE r

Maximum Recommended Pump Speed

60 cycles/min

 

 

Maximum Hydraulic Motor Fluid Temperature

. 54_C (134_F)

PTFEr￿ is a registered trademark of the DuPont Co.

Hydraulic Fluid Inlet

. . . . . . . . . . .

3/4”, (37_ flare)

Hydraulic Fluid Outlet

. . . . . . . . . . .

7/8”, (37_ flare)

Loctiter￿ is a registered trademark of the Loctite Corp.

PUMP OUTLET PRESSURE

MPa, BAR

PSI

12

24 CPM 36

48

60

 

 

l/min

2.1, 21

3￿￿

 

 

 

 

 

 

 

 

 

 

 

GPM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

22.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.7, 17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿5￿

 

 

 

 

 

 

 

 

 

 

 

5

 

19.0

 

 

A

 

 

 

 

 

 

 

 

 

1.4, 14

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿

 

 

 

 

 

 

 

 

 

4

 

15.2

 

 

 

 

 

 

 

 

 

 

 

 

1.05, 10.5

￿5￿

 

 

 

 

 

 

 

 

 

 

 

3

 

11.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

0.7, 7

￿￿￿

 

 

 

 

 

 

 

 

 

 

 

2

 

7.6

0.35, 3.5

5￿

 

 

C

 

 

 

 

 

 

 

 

1

 

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GPM ￿

4

8

￿￿

￿6

￿￿

 

l/min

15

30

46

62

76

 

 

 

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

HYDRAULIC OIL CONSUMPTION

A10.3 MPa, 103 bar (1500 psi) hydraulic oil pressure

B6.9 MPa, 69 bar (1000 psi) hydraulic oil pressure

C3.4 MPa, 34 bar (500 psi) hydraulic oil pressure

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating hydraulic pressure (MPa/bar/ psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected fluid outlet pressure curve (black urves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

To find Motor Hydraulic Oil Consumption (liter/min or gpm) at a specific delivery (liter/min or gpm) :

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with hydraulic oil consumption curve (gray curve). Curve slopes from right to left. Follow right to scale and read hydraulic oil consumption.

Manual Change Summary

Assembly

Part

Ref.

Part No.

Name

Changed

Status

No.

 

 

Models

Old

202

214–034

Drum Cover

220–574 &

New

202

237–309

Drum Cover

220–575

Added

208

100–839

Elbow

President

 

 

 

 

Pumps, to

 

 

 

 

Series B

 

 

 

 

Model 239–815 4:1 Bulldog Pump and Model 239–816 Displacement Pump are added to the manual.

Model 239–819 3:1 President Pump and Model 239–820 Displacement Pump are added to the manu- al.

￿07-809 47

Image 47
Contents Rev. T Supersedes N and PCN R includes Rev. S Refer to page 2 for the Table of ContentsINSTRUCTIONS-PARTSLIST 307-809Table of Contents SEVERE-DUTYELECTROPOLISHED STAINLESS STEEL MODELS Ratio and Type parts list pagesPump Models CARBON STEEL MODELSEQUIPMENT MISUSE HAZARD SymbolsWarning Symbol Caution SymbolTOXIC FLUID HAZARD FIRE AND EXPLOSION HAZARDPage Plumbing Installation All PumpsTypical Installation Mount the PumpFluid Line from Pump Installation Air-PoweredPumpsAir Line to Motor Installation Air-PoweredPumps Hydraulic Return from Motor Installation Hydraulic-PoweredPumpsHydraulic Power Supply Hydraulic Supply to MotorP Q R Installation Hydraulic-PoweredPumpsFlush the Pump Before First Use Pressure Relief ProcedureOperation All Pumps Before You Start the PumpShutdown Operation Air-PoweredPumpsStarting and Adjusting the Pump Shutdown Operation Hydraulic-PoweredPumpsStarting and Adjusting the Pump Excessive Leaking at Throat MaintenanceFlushing Packing Nut TightnessAir Line Filter Hydraulic Power Supply CheckMix Tank Volume Air Line LubricatorCAUSE TroubleshootingPROBLEM SOLUTIONFor President air-poweredpumps ServiceDisconnecting the Displacement Pump Reconnecting the Displacement PumpModel Model 220-569 Senator Pump ShownModel 236-601 Viscount I+ Pump Shown Model 220-564 President Pump ShownService Disassembling the Displacement PumpCleaning and Inspecting Parts Repair KitsService OUTLETINLET Service Reassembling the Displacement Pump OUTLET Side View of Outlet Housing  ServiceSTAINLESS STEEL PUMPS Parts President PumpsCARBON STEEL PUMPS SEVERE-DUTY,ELECTROPOLISHEDCARBON STEEL PUMPS SEVERE-DUTY,ELECTROPOLISHED STAINLESS STEEL PUMPSModel 237-222,Series A, 3 1 Ratio104 Parts President PumpsParts President Pumps Assembly ProcedureModel 220-574,Series B Model 220-575,Series B  with 55 gal. drum cover and agitator3 1 Ratio Carbon Steel President Pump 3 1 Ratio Stainless Steel President PumpModel 220-567,Series A, 2.5 1 Ratio Parts Quiet Senator PumpsModel 220-565,Series A, 3.5 1 Ratio Model 220-566,Series A, 5 1 RatioModel 239-815,Series A , 4 1 Ratio Parts Quiet Bulldog PumpsModel 220-577,Series A, 4 1 Ratio Model 220-578,Series A , 4 1 RatioPage Model 236-712,Series A Parts Viscount I+ PumpsSEVERE-DUTY,ELECTROPOLISHED STAINLESS STEEL PUMPS Model 236-601,Series A Model 236-605,Series AModel 220-549,Series D CARBON STEEL DISPLACEMENT PUMPSParts Parts MatrixModel 220-549,Series D Model 220-549ShownCARBON STEEL DISPLACEMENT PUMPS PartsModel 239-820,Series A for Pump Model PartsParts Matrix Model 237-220,Series A for Pump Model PartsPump Seal Kit Repair KitsPump Seal Kit Pump Seal KitBolt Pattern DimensionsSurge Stand Mounting HoleMedium Volume High-FloSurge Tank AccessoriesUse Only Genuine Graco Parts and Accessories Grounding Wire and ClampWall Bracket Mounting Stand KitPump Floor Stand Stationary StandTechnical Data AIR CONSUMPTION Technical DataMaximum Working Pressure PUMP OUTLET PRESSURETechnical Data AIR CONSUMPTION Technical DataMPa, BAR PSI PUMP OUTLET PRESSUREPage PUMP OUTLET PRESSURE Technical Data3789 MPa, BAR3789 Viscount I+ Pumps, Models 236-601andViscount I+ Pumps, Models 236-605and Technical DataTechnical Data Manual Change SummaryViscount I+ Pumps, Models 236-712and FOR GRACO CANADA CUSTOMERS The Graco Warranty and DisclaimersGraco Phone Number