Technical Data
1.5:1 Ratio President Pumps, Models
Maximum Working Pressure . . . . . 1.9 MPa, 19 bar (270 psi) Air Operating Range .
Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model
|
|
|
|
|
| CPM |
|
|
|
|
| |
| MPa, BAR | PSI |
| 10 | 18 | 27 | 36 | 45 | 54 | 63 |
|
|
| 2.8, 28 | 400 |
|
|
|
|
|
|
| CFM | m3/min | |
| 2.45, 24.5 | 350 |
|
|
|
|
|
|
| 70 | 1.96 |
|
PUMP OUTLET PRESSURE | 2.1, 21 | 300 |
|
|
|
|
|
|
| 60 | 1.68 | AIR CONSUMPTION |
1.7, 17 | 250 |
|
|
|
|
|
|
| 50 | 1.40 | ||
1.4, 14 | 200 |
|
|
|
|
|
|
| 40 | 1.12 | ||
1.05, 10.5 | 150 | A |
|
|
|
| B | A | 30 | 0.84 | ||
0.7, 7 | 100 | B |
|
|
| C |
| 20 | 0.56 | |||
0.35, 3.5 | 50 | C |
|
|
|
|
| 10 | 0.28 | |||
|
|
|
|
|
|
|
| |||||
|
| 0 |
|
|
|
|
|
|
| 0 |
|
|
| GPM | 0 | 3 | 6 | 9 | 12 | 15 | 18 | 21 |
|
| |
| l/min |
| 11 | 23 | 34 | 46 | 57 | 68 | 79 |
|
|
PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)
A0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure
To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):
1.Locate desired delivery along bottom of chart.
2.Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.
To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):
1.Locate desired delivery along bottom of chart.
2.Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.
2:1 Ratio President Pumps, Models
Maximum Working Pressure | . . . . . | 2.5 MPa, 25 bar (360 psi) |
| Fluid Inlet | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | ||||||||||
Air Operating Range | . |
| Fluid Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1” npt | ||||||||||||
Air Consumption | . . . . . . . . . . . . . . . . . See Performance Chart |
| Wetted Parts |
| |||||||||||
Continuous Duty Delivery . . . . . . . . . . . 55 liter/min (14.6 gpm) |
|
| Model | ||||||||||||
Pump Cycles Per Liter (gallon) | 1.0 (4.1) |
|
| ||||||||||||
Maximum Recommended Pump Speed | . . . . . | 60 cycles/min |
|
| Model | ||||||||||
Air Inlet | 1/2 npt(f) |
|
| ||||||||||||
| MPa, BAR | PSI |
|
|
|
| CPM |
|
|
|
|
|
|
|
|
|
| 8 | 16 | 25 | 33 | 41 | 49 | 57 | 66 |
|
|
|
| ||
| 2.8, 28 | 400 |
|
|
|
|
|
|
|
| CFM m3/min | A 0.7 MPa, 7 bar (100 psi) air pressure | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B 0.49 MPa, 4.9 bar (70 psi) air pressure |
| 2.45, 24.5 | 350 |
|
|
|
|
|
|
|
|
| 70 | 1.96 |
| C 0.28 MPa, 2.8 bar (40 psi) air pressure |
|
|
|
|
|
|
|
|
|
|
|
| ||||
PUMPOUTLET PRESSURE | 2.1, 21 | 300 |
|
|
|
|
|
|
|
|
| 60 | 1.68 |
| To find Outlet Pressure (MPa/bar/psi) at a specific |
|
|
|
|
|
|
|
|
| AIR CONSUMPTION | delivery (liter/min or gpm) and operating air pressure | |||||
1.7, 17 | 250 |
|
|
|
|
|
|
|
|
| 50 | 1.40 | (MPa/bar/psi): | ||
|
|
|
|
|
|
|
|
| 1. Locate desired delivery along bottom of chart. | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
| 2. Read vertical line up to intersection with | ||
1.4, 14 | 200 |
| A |
|
|
|
|
|
|
| 40 | 1.12 | selected fluid outlet pressure curve (black | ||
|
|
|
|
|
|
|
| curves). Curve slopes from left to right. | |||||||
| 150 |
|
|
|
|
|
|
|
|
|
| Follow left to scale and read outlet pressure. | |||
1.05, 10.5 |
|
|
|
|
|
|
|
|
| 30 | 0.84 | ||||
| B |
|
|
|
| A | B |
| To find Pump Air Consumption (m3/min or | ||||||
|
|
|
|
|
|
|
|
|
| ||||||
0.7, 7 | 100 |
|
|
|
|
|
| 20 | 0.56 | CFM/min) at a specific delivery (liter/min or gpm) | |||||
| C |
|
|
| C |
|
| and operating air pressure (MPa/bar/psi): | |||||||
| 50 |
|
|
|
|
|
|
|
| 1. Locate desired delivery along bottom of chart. | |||||
| 0.35, 3.5 |
|
|
|
|
|
|
|
|
| 10 | 0.28 |
| 2. Read vertical line up to intersection with | |
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
| selected air consumption curve (gray curves). |
|
|
|
|
|
|
|
|
|
|
| 0 |
|
| Curve slopes from right to left. Follow right to | |
| GPM | 0 | 2 | 4 | 6 | 8 | 10 | 12 | 14 | 16 |
|
| scale and read air consumption. | ||
|
|
|
|
| |||||||||||
| l/min |
| 8 | 15 | 23 | 30 | 38 | 46 | 54 | 62 |
|
|
|
| |
|
| PUMP DELIVERY (Test Fluid: No. 10 Motor Oil) |
|
|
|
|
4 3