Graco 220-569 manual Technical Data

Page 42
Manual background

Technical Data

3.5:1 Ratio Quiet Senator Pumps, Models 220–565 and 220–568

Maximum Working Pressure . . 2.45 MPa, 24.5 bar (350 psi) Air Operating Range . 0.28–0.7 MPa, 2.8–7 bar (40–100 psi) Air Consumption . . . . . . . . . . . . . . . . . See Performance Chart Continuous Duty Delivery . . . . . . . . . 65.8 liter/min (17.4 gpm) Pump Cycles Per Liter (gallon) . . . . . . . . . . . . . . . . 0.91 (3.44) Maximum Recommended Pump Speed . . . . . 60 cycles/min Air Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f)

Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1/2” npt(f) Fluid Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1” npt Wetted Parts

Model 220–565 . . . . . . . . . Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE r Model 220–568 . . . . . . . . Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE r

 

MPa, BAR

PSI

 

10

21

CPM

52

62

72

 

 

 

 

 

31

41

 

 

 

 

2.45, 24.5

350

 

 

 

 

 

 

 

CFM m3/min

 

 

 

 

 

 

 

 

 

 

PUMP OUTLET PRESSURE

2.1, 21

300

 

A

 

 

 

 

 

 

60

1.68

 

1.7, 17

250

 

 

 

 

 

 

 

 

50

1.40

AIR CONSUMPTION

1.4, 14

200

 

B

 

 

 

 

 

 

40

1.12

 

 

 

 

 

A

 

 

1.05, 10.5

150

 

 

 

 

 

 

 

30

0.84

 

C

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

0.7, 7

100

 

 

 

 

 

 

 

20

0.56

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

0.35, 3.5

50

 

 

 

 

 

 

 

 

10

0.28

 

 

0

0

3

6

9

12

15

18

21

0

 

 

 

GPM

 

 

 

l/min

 

11

23

34

46

57

68

79

 

 

 

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

A0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

2.5:1 Ratio Quiet Senator Pumps, Models 220–567 and 220–570

Maximum Working Pressure . . . . . 1.7 MPa, 17 bar (250 psi) Air Operating Range . 0.28–0.7 MPa, 2.8–7 bar (40–100 psi) Air Consumption . . . . . . . . . . . . . . . . . See Performance Chart Continuous Duty Delivery . . . . . . . . . . . 89.9 liter/min (24 gpm) Pump Cycles Per Liter (gallon) . . . . . . . . . . . . . . . . . 0.66 (2.5) Maximum Recommended Pump Speed . . . . . 60 cycles/min Air Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f)

Fluid Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1–1/2” npt(f) Fluid Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1” npt Wetted Parts

Model 220–567 . . . . . . . . . Carbon Steel, Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE r Model 220–570 . . . . . . . . Chrome-Plated Stainless Steel, Ultra-High Molecular Weight Polyethylene, Leather, PTFE r

 

 

 

 

 

CPM

 

 

 

 

 

 

MPa, BAR PSI

13

25

38

50

63

75

88

 

 

 

1.7, 17

250

 

 

 

 

 

 

CFMm3/min

 

 

 

A

 

 

 

 

 

 

50 1.40

 

 

 

 

 

 

 

 

 

 

 

 

PUMP OUTLET PRESSURE

1.4, 14

200

 

 

 

 

 

 

 

40 1.12

 

1.05, 10.5

150

B

 

 

 

A

 

 

30 0.84

AIR CONSUMPTION

 

 

 

 

 

 

0.7, 7

100

C

 

 

B

 

 

 

20 0.56

0.35, 3.5

50

 

 

 

 

 

 

10 0.28

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

0

 

 

GPM 0

5

10

15

20

25

30

35

 

 

l/min

19

38

57

76

95

114

133

 

 

PUMP DELIVERY (Test Fluid: No. 10 Motor Oil)

A0.7 MPa, 7 bar (100 psi) air pressure B 0.49 MPa, 4.9 bar (70 psi) air pressure C 0.28 MPa, 2.8 bar (40 psi) air pressure

To find Outlet Pressure (MPa/bar/psi) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected fluid outlet pressure curve (black curves). Curve slopes from left to right. Follow left to scale and read outlet pressure.

To find Pump Air Consumption (m3/min or CFM/min) at a specific delivery (liter/min or gpm) and operating air pressure (MPa/bar/psi):

1.Locate desired delivery along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (gray curves). Curve slopes from right to left. Follow right to scale and read air consumption.

4￿ ￿￿7￿8￿9

Image 42
Contents 307-809 Refer to page 2 for the Table of ContentsINSTRUCTIONS-PARTSLIST Rev. T Supersedes N and PCN R includes Rev. STable of Contents CARBON STEEL MODELS Ratio and Type parts list pagesPump Models SEVERE-DUTYELECTROPOLISHED STAINLESS STEEL MODELSCaution Symbol SymbolsWarning Symbol EQUIPMENT MISUSE HAZARDFIRE AND EXPLOSION HAZARD TOXIC FLUID HAZARDPage Mount the Pump Installation All PumpsTypical Installation PlumbingInstallation Air-PoweredPumps Air Line to MotorFluid Line from Pump Installation Air-PoweredPumps Hydraulic Supply to Motor Installation Hydraulic-PoweredPumpsHydraulic Power Supply Hydraulic Return from MotorInstallation Hydraulic-PoweredPumps P Q RBefore You Start the Pump Pressure Relief ProcedureOperation All Pumps Flush the Pump Before First UseOperation Air-PoweredPumps Starting and Adjusting the PumpShutdown Operation Hydraulic-PoweredPumps Starting and Adjusting the PumpShutdown Packing Nut Tightness MaintenanceFlushing Excessive Leaking at ThroatAir Line Lubricator Hydraulic Power Supply CheckMix Tank Volume Air Line FilterSOLUTION TroubleshootingPROBLEM CAUSEReconnecting the Displacement Pump ServiceDisconnecting the Displacement Pump For President air-poweredpumpsModel 220-564 President Pump Shown Model 220-569 Senator Pump ShownModel 236-601 Viscount I+ Pump Shown ModelRepair Kits Disassembling the Displacement PumpCleaning and Inspecting Parts ServiceOUTLET INLETService Reassembling the Displacement Pump Service Service Side View of Outlet Housing  OUTLETSEVERE-DUTY,ELECTROPOLISHED Parts President PumpsCARBON STEEL PUMPS STAINLESS STEEL PUMPSParts President Pumps SEVERE-DUTY,ELECTROPOLISHED STAINLESS STEEL PUMPSModel 237-222,Series A, 3 1 Ratio104 CARBON STEEL PUMPSModel 220-575,Series B Assembly ProcedureModel 220-574,Series B Parts President Pumps3 1 Ratio Stainless Steel President Pump with 55 gal. drum cover and agitator3 1 Ratio Carbon Steel President Pump  Model 220-566,Series A, 5 1 Ratio Parts Quiet Senator PumpsModel 220-565,Series A, 3.5 1 Ratio Model 220-567,Series A, 2.5 1 RatioModel 220-578,Series A , 4 1 Ratio Parts Quiet Bulldog PumpsModel 220-577,Series A, 4 1 Ratio Model 239-815,Series A , 4 1 RatioPage Model 236-601,Series A Model 236-605,Series A Parts Viscount I+ PumpsSEVERE-DUTY,ELECTROPOLISHED STAINLESS STEEL PUMPS Model 236-712,Series AParts Matrix CARBON STEEL DISPLACEMENT PUMPSParts Model 220-549,Series DParts Model 220-549ShownCARBON STEEL DISPLACEMENT PUMPS Model 220-549,Series DParts Parts MatrixModel 239-820,Series A for Pump Model Parts Model 237-220,Series A for Pump ModelPump Seal Kit Repair KitsPump Seal Kit Pump Seal KitMounting Hole DimensionsSurge Stand Bolt PatternGrounding Wire and Clamp AccessoriesUse Only Genuine Graco Parts and Accessories Medium Volume High-FloSurge TankStationary Stand Mounting Stand KitPump Floor Stand Wall BracketTechnical Data PUMP OUTLET PRESSURE Technical DataMaximum Working Pressure AIR CONSUMPTIONTechnical Data PUMP OUTLET PRESSURE Technical DataMPa, BAR PSI AIR CONSUMPTIONPage MPa, BAR Technical Data3789 PUMP OUTLET PRESSURETechnical Data Viscount I+ Pumps, Models 236-601andViscount I+ Pumps, Models 236-605and 3789Manual Change Summary Viscount I+ Pumps, Models 236-712andTechnical Data The Graco Warranty and Disclaimers Graco Phone NumberFOR GRACO CANADA CUSTOMERS