La Crosse Technology WS-7394U-IT instruction manual Multiple Remote Temperature Sensors

Page 15

Note: To reset the outdoor minimum and maximum temperature, first display the values you wish to reset (minimum or maximum). Next press and hold the “SET” key for at least three seconds. You will see then that the values will reset to the current temperature and corresponding time.

B. Multiple Remote Temperature Sensors

The WS-7394U-IT is able to receive signals from 2 additional temperature sensors. The following are instructions for the set-up of temperature sensor units with the WS-7394U-IT. These extra sensors can be purchased through the same dealer as this unit.

1.Remove all the batteries from the receiver and sensor(s) and wait 60 seconds. During these 60 seconds, press any button 20 times to discharge any excess power.

2.Insert the batteries to the first temperature sensor.

3.Within 2 minutes of powering up the first sensor, insert the batteries to the Weather Station. Once the batteries are in place, all segments of the LCD will light up briefly. Following the indoor temperature and humidity, and the time as 12:00 will be displayed. If they are not shown in LCD after 60 seconds, remove the batteries and wait for at least 60 seconds before reinserting them.

4.The outdoor temperature from the first sensor (channel 1) should then be displayed on the Weather Station. If this does not happen and the signal reception icon is not shown, after 2 minutes, the batteries will need to be removed from both units and reset from step 1.

5.Insert the batteries to the second sensor as soon as the outdoor temperature readings from the first sensor are displayed on the Weather Station.

NOTE: You must insert the batteries into the second sensor within 10 seconds of reception of the first sensor.

6.The outdoor temperature from the second sensor and the "channel 2" icon should then be displayed on the Weather Station. If this does not happen after 2 minute, the batteries will need to be removed from all the units and reset from step 1.

7.Insert the batteries to the third sensor as soon as the "channel 2" icon and outdoor data are displayed on the Weather Station. Then within 2 minutes, the channel 3 outdoor data from the third sensor will be displayed and the channel icon will shift back to "1" once the third sensor is successfully received. If this is not happen, user shall restart the setting up from step 1.

NOTE: You must insert the batteries into the third sensor within 10 seconds of reception of the second sensor.

IMPORTANT: Transmission problems will arise if the setting for multiple sensors is not followed as described above. Should transmission problems occur, it is necessary to remove the batteries from all units and start again the set-up from step 1.

C.Viewing and Operating with Multiple Remote Sensors

a.To view the temperature of a different remote sensor press and release the “CH” button. A shift from one “boxed” number to the next should be observed in the OUTDOOR LCD.

15

Image 15
Contents WS-7394U-IT Wireless 915 MHz Wireless Weather Station Table of Contents This product offers Inventory of ContentsWeather Station Quick SET-UP GuideRemote Temperature Sensor Wireless Weather StationDetailed SET-UP Guide Wwvb Reception II. Start Up Sequence Initial StartIII. Explanation of LCD Information IV. Function Key Layout Program ModeOverview of programming mode sequence LCD Contrast SettingTime Zone Setting DST ON/OFF SettingRadio-Controlled Time ON/OFF Setting Setting The Hour Manually 12/24-hour Time ModeSetting The Date Manually Setting The Minutes ManuallySetting The Year Manually Setting The Month ManuallyTemperature Measuring Units Selection F or C Relative Pressure SettingAir Pressure Measuring Units Selection inHg/hPa Manual Setting is NOW Completed Forecast Sensitivity SettingOutdoor Minimum and Maximum Temperature Features and OperationsViewing and Operating with Multiple Remote Sensors Multiple Remote Temperature SensorsComfort Indicator for Indoor Temperature and Humidity Weather Forecast Icon and Pressure Trend IndicatorsWeather Icons Air Pressure History Bar Chart Weather Tendency ArrowsBarometric Air Pressure Reading Mounting with Adhesive Tape Mounting the Remote Temperature SensorVII. Mounting Mounting with ScrewsWall Mounting Mounting the WS-7394U-IT Wireless Weather StationUsing the Table Stand Maintenance and Care InstructionsSpecifications TroubleshootingProblem SolutionAir pressure Sensor reading update within sensorPower supply Relative humidity rangePage FCC ID OMOTX29U sensor RF Exposure mobile WS-7013U-IT Table of Contents Inventory of Contents Quick Setup Do not Press ANY Buttons for Minutes Page Page Detailed Setup Guide Remote Temperature Sensor Remove the mounting Page Page Setting the Time Features Page Page Page To wall mount MountingTroubleshooting Solution Maintenance and Care Measuring Temperatures SpecificationsDimensions H x W x D Warranty InformationPage Page Page Fax Mail Support@lacrossetechnology.com Warranty work Web FCC ID OMOTX29U sensor RF Exposure mobile