3.Place the batteries into the remote temperature sensor first then into the indoor temperature station.

(All remote temperature sensors must be started before the indoor temperature station)

4.DO NOT PRESS ANY BUTTONS FOR

15 MINUTES.

In this time the indoor temperature station and remote temperature sensor will start to talk to each other and the display will show both the indoor temperature and an outdoor temperature. If the indoor temperature station does not display both temperatures after the 15 minutes please retry the set up as stated above. After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoors and set your time.

The remote temperature sensor should be placed in a dry, shaded area. The thermo- hygro sensor has a range of 330 feet. Keep in mind that the 330 feet is in open air with no obstructions and that radio waves DO NOT curve around objects. Actual transmission range will vary depending on what is in the path of the signal. Each obstruction (roof,

5

Image 28
Contents WS-7394U-IT Wireless 915 MHz Wireless Weather Station Table of Contents Inventory of Contents This product offersQuick SET-UP Guide Weather StationWireless Weather Station Remote Temperature SensorDetailed SET-UP Guide II. Start Up Sequence Initial Start Wwvb ReceptionIII. Explanation of LCD Information Program Mode Overview of programming mode sequenceLCD Contrast Setting IV. Function Key LayoutDST ON/OFF Setting Time Zone SettingRadio-Controlled Time ON/OFF Setting 12/24-hour Time Mode Setting The Hour ManuallySetting The Minutes Manually Setting The Year ManuallySetting The Month Manually Setting The Date ManuallyRelative Pressure Setting Temperature Measuring Units Selection F or CAir Pressure Measuring Units Selection inHg/hPa Forecast Sensitivity Setting Manual Setting is NOW CompletedFeatures and Operations Outdoor Minimum and Maximum TemperatureMultiple Remote Temperature Sensors Viewing and Operating with Multiple Remote SensorsWeather Forecast Icon and Pressure Trend Indicators Comfort Indicator for Indoor Temperature and HumidityWeather Icons Weather Tendency Arrows Air Pressure History Bar ChartBarometric Air Pressure Reading Mounting the Remote Temperature Sensor VII. MountingMounting with Screws Mounting with Adhesive TapeMounting the WS-7394U-IT Wireless Weather Station Using the Table StandMaintenance and Care Instructions Wall MountingTroubleshooting ProblemSolution SpecificationsSensor reading update within sensor Power supplyRelative humidity range Air pressurePage FCC ID OMOTX29U sensor RF Exposure mobile WS-7013U-IT Table of Contents Inventory of Contents Quick Setup Do not Press ANY Buttons for Minutes Page Page Detailed Setup Guide Remote Temperature Sensor Remove the mounting Page Page Setting the Time Features Page Page Page Mounting To wall mountTroubleshooting Solution Maintenance and Care Specifications Measuring TemperaturesWarranty Information Dimensions H x W x DPage Page Page Fax Mail Support@lacrossetechnology.com Warranty work Web FCC ID OMOTX29U sensor RF Exposure mobile