Friedrich R410A manual Vpak 9-18K BTU Units Components Identification, Ground Air Intake

Page 15

VPAK 9-18K BTU UNITS

COMPONENTS IDENTIFICATION

Nameplate

 

Air Discharge

 

 

 

Ground

Air Intake

Front Side

Right Side

Blower Wheel and

Heater in here

10” Duct Collar

Condenser

Heater

Diagnostic

Touch Pad

Pullout

Disconnect

Compressor

Blower/Fan

Motor Capacitor

Fresh Air

Vent

Evaporator

Coil

Condenser

Coil Thermistor

Compressor

Evaporator

Coil Thermistor

Evaporator Coil

Fresh Air

Vent Door

Heater

Blower

Wheel

Condenser

Air Intake

Condenser

Blower/Fan

Motor

Condenser

Fan Shroud

Condenser

Air Discharge

Left and Front Sides

Left and Back Sides

14

Image 15
Contents Single Package Vertical Air Conditioning System Table of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards IntroductionProduct Line 00001Serial Number Year Manufactured Production RUN NumberElectrical Requirements Chassis Specifi cations Cooling Performance Data Technical Service DataQuiet Start/Stop Electronic Control Board FeaturesHeat Mode in Cool with Electric Heat Units Compressor Lock Out Time Electric Shock Hazard Low Voltage Interface ConnectionsCUT/SEVER Hazard ServiceGround Air Intake Vpak 9-18K BTU Units Components IdentificationAir Intake Front Side Vpak 24K BTU Units Components IdentificationError Codes and Alarm Status Components Testing Fuse 10 Amps 250 VaC Blower / FAN Motor Test Capacitor Check with Capacitor AnalyzerCapacitor Connections Blower / FAN MotorDrain PAN Valve Heater Elements and Limit SWITCHES’ SpecificationsExternal Static Pressure Explanation of charts Refrigeration Sequence of Operation Refrigeration AssemblyRisk of Electric Shock Sealed Refrigeration System RepairsEquipment Required Equipment Must be CapableFreeze Hazard Method Of Charging / RepairsUndercharged Refrigerant Systems Burn HazardRestricted Refrigerant System Overcharged Refrigerant SystemsCapillary Tube Systems Cooling ModeHeating Mode Hermetic Components CheckReversing Valve DESCRIPTION/OPERATION Procedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleFire Hazard Determine L.R.V Single Phase ConnectionsSingle Phase Running and L.R.A. Test Locked Rotor Voltage L.R.V. TestGround Test Single Phase Resistance TestExternal Overload Vpak 9, 12, 18 K Btus Internal Overload Vpak 24 K BtusHigh Temperatures Recommended procedure for compressor replacementElectrical Shock Hazard Routine MaintenanceRoom AIR Conditioner Unit Performance Test Data Sheet THERMISTORS’ Resistance Values 9K BTU, 12K BTU, & 18K BTU Electrical Troubleshooting Chart CoolingCompressor outdoor Electrical Troubleshooting Chart Cooling 24K BTUHeat Pump Mode Electrical Troubleshooting Chart Heat PumpTroubleshooting Chart Heating Heat Pump Troubleshooting Chart CoolingHeat Pump with Electric Heat Remote Wall Thermostat Wiring DiagramsGH GL B Y RT6 6TR Cool with Electric HeatGH GL B Y W R GH GL O/B Y W Wiring Diagram Heat Pump EH 5KW, 10.0KW Model Description Photo Friedrich Air Conditioning Company Vpak 9K-18K BTU/h Models Vpak 9K-18K BTU/h Models Vpak 9K-18K BTU/h Models Vpak 9K-18K BTU/h Models 9K-18K BTU/h Models Vpak Parts List Vpak 24K BTU/h Models Vpak 24K BTU/h Models Vpak 24K BTU/h Models Vpak 24K BTU/h Models 24K BTU/h Models Vpak Parts List Technical Support Contact Information Friedrich AIR Conditioning CO
Related manuals
Manual 45 pages 45.67 Kb Manual 7 pages 15.54 Kb Manual 27 pages 24.75 Kb