Friedrich R410A manual 00001, Serial Number, Year Manufactured Production RUN Number, Product Line

Page 6

 

MODEL IDENTICATION GUIDE

 

 

 

 

 

 

 

 

 

 

 

MODEL NUMBER

 

 

V

E

A

18

K

50

RT

L-B

 

 

 

 

 

 

 

 

 

 

L; MARKETING SUFFIX

SERIES

 

 

 

 

 

 

 

 

 

V=Vertical Series

 

 

 

 

 

 

 

 

 

Indicates Modification (subject to change)

 

 

 

 

 

 

 

 

 

 

B; ENGINEERING SUFFIX

E=Cooling with or without electric heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates Modification (subject to change)

H=Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESIGN SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RT = Standard Wired Remote

A = 32" and 47" Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T-stat Operation

 

 

 

 

 

 

 

 

 

 

NOMINAL CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HEATER SIZE

A-SERIES (BTU/H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A-SERIES

09 = 9,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 = No electric heat

12 = 12,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 = 2.5 KW

18 = 18,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34 = 3.4 KW

24 = 24,000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 = 5.0 KW

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

 

75 = 7.5 KW

K = 208/230V-1Ph-60Hz

 

 

 

 

 

 

 

 

 

10 = 10 KW

 

 

 

 

 

 

 

 

 

 

 

 

VPAK SERIAL NUMBER IDENTIFICATION GUIDE

SERIAL NUMBER

A

A

A

N

00001

YEAR MANUFACTURED

 

 

 

 

PRODUCTION RUN NUMBER

AK = 2010

AE = 2015

 

 

 

 

 

AA = 2011

AF = 2016

 

 

 

 

 

AB = 2012

AG = 2017

 

 

 

 

PRODUCT LINE

 

 

 

 

 

 

N = VPAK

AD = 2014

AJ = 2019

 

 

 

 

 

MONTH MANUFACTURED

 

 

 

 

 

A = Jan

D = Apr

G = Jul

K = Oct

 

 

 

B = Feb

E = May

H = Aug

L = Nov

 

 

 

C = Mar

F = Jun

J = Sep

M = Dec

 

 

 

SampleNameplate(seeyourchassis nameplate)

120524

COOLING EQUIPMENT

FOLLOWING ITEMS

OUTDOOR GRILLE

INDOOR GRILLE

5

Image 6
Contents Single Package Vertical Air Conditioning System Table of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Hazards Introduction Property Damage HazardsYear Manufactured Production RUN Number 00001Serial Number Product LineElectrical Requirements Chassis Specifi cations Technical Service Data Cooling Performance DataElectronic Control Board Features Quiet Start/StopHeat Mode in Cool with Electric Heat Units Compressor Lock Out Time Low Voltage Interface Connections Electric Shock HazardService CUT/SEVER HazardVpak 9-18K BTU Units Components Identification Ground Air IntakeVpak 24K BTU Units Components Identification Air Intake Front SideError Codes and Alarm Status Components Testing Fuse 10 Amps 250 VaC Blower / FAN Motor Capacitor Check with Capacitor AnalyzerCapacitor Connections Blower / FAN Motor TestHeater Elements and Limit SWITCHES’ Specifications Drain PAN ValveExternal Static Pressure Explanation of charts Refrigeration Assembly Refrigeration Sequence of OperationEquipment Must be Capable Sealed Refrigeration System RepairsEquipment Required Risk of Electric ShockBurn Hazard Method Of Charging / RepairsUndercharged Refrigerant Systems Freeze HazardOvercharged Refrigerant Systems Restricted Refrigerant SystemHermetic Components Check Cooling ModeHeating Mode Capillary Tube SystemsReversing Valve DESCRIPTION/OPERATION Procedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleFire Hazard Locked Rotor Voltage L.R.V. Test Single Phase ConnectionsSingle Phase Running and L.R.A. Test Determine L.R.VInternal Overload Vpak 24 K Btus Single Phase Resistance TestExternal Overload Vpak 9, 12, 18 K Btus Ground TestRecommended procedure for compressor replacement High TemperaturesRoutine Maintenance Electrical Shock HazardRoom AIR Conditioner Unit Performance Test Data Sheet THERMISTORS’ Resistance Values Electrical Troubleshooting Chart Cooling 9K BTU, 12K BTU, & 18K BTUElectrical Troubleshooting Chart Cooling 24K BTU Compressor outdoorElectrical Troubleshooting Chart Heat Pump Heat Pump ModeTroubleshooting Chart Cooling Troubleshooting Chart Heating Heat PumpRemote Wall Thermostat Wiring Diagrams Heat Pump with Electric HeatGH GL B Y RT6 Cool with Electric Heat 6TRGH GL B Y W R GH GL O/B Y W Wiring Diagram Heat Pump EH 5KW, 10.0KW Model Description Photo Friedrich Air Conditioning Company Vpak 9K-18K BTU/h Models Vpak 9K-18K BTU/h Models Vpak 9K-18K BTU/h Models Vpak 9K-18K BTU/h Models 9K-18K BTU/h Models Vpak Parts List Vpak 24K BTU/h Models Vpak 24K BTU/h Models Vpak 24K BTU/h Models Vpak 24K BTU/h Models 24K BTU/h Models Vpak Parts List Technical Support Contact Information Friedrich AIR Conditioning CO
Related manuals