PROCEDURE FOR CHANGING DRIVE AND IDLE ROLL SETS

1.Turn off the power source.

2.Release the pressure on the idle roll by swinging the adjustable pressure arm down toward the back of the machine. Lift the cast idle roll assembly and allow it to sit in an upright position..

3.Remove the outside wire guide retaining plate by loosening the two large knurled screws.

4.Wiggle both the metal idle and drive rolls off of their plastic hubs.

5.Remove the inside wire guide plate.

6.Replace the drive and idle rolls and inside wire guide with a set marked for the new wire size. NOTE: Be sure that the gun liner and contact tip are also sized to match the selected wire size.

7.Manually feed the wire from the wire reel, over the drive roll groove and through the wire guide and then into the brass bushing of the gun and cable assembly.

8.Replace the outside wire guide retaining plate by tightening the two large knurled screws. Reposition the adjustable pressure arm to its original position to apply pressure. Adjust pressure as necessary.

WIRE REEL LOADING - READI-REELS, SPOOLS OR COILS

To Mount a 30 Lb. (14 kg) Readi-Reel Package (Using the Molded Plastic K363-P Readi-Reel Adapter:)

1.Open the Wire Drive Compartment Door.

2.Depress the Release Bar on the Retaining Collar and remove it from the spindle.

3.Place the Optional Adapter on the spindle

4.Re-install the Retaining Collar. Make sure that the Release Bar “pops up” and that the collar retainers fully engage the retaining ring groove on the spindle.

5.Rotate the spindle and adapter so the retaining spring is at the 12 o'clock position.

6.Position the Readi-Reel so that it will rotate in a direction when feed- ing so as to be de- reeled from top of the coil.

7.Set one of the Readi-Reel inside cage wires on the slot in the retain- ing spring tab.

8.Lower the Readi-Reel to depress the retaining spring and align the other inside cage wires with the grooves in the molded adapter.

9.Slide cage all the way onto the adapter until the retaining spring "pops up" fully.

CAUTION

CHECK TO BE SURE THE RETAINING SPRING HAS FULLY RETURNED TO THE LOCKING POSITION AND HAS SECURELY LOCKED THE READI-REEL CAGE IN PLACE. RETAINING SPRING MUST REST ON THE CAGE, NOT THE WELDING ELECTRODE.

-----------------------------------------------------------------------------------------------

10.To remove Readi-Reel from Adapter, depress retaining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands. Do not remove adapter from spindle.

FIGURE B.2

To Mount 10 to 44 Lb. (4.5-20 kg) Spools (12"/300 mm Diameter) or 14Lb.(6 Kg) Innershield Coils:

(For 13-14 lb. (6 Kg) Innershield coils, a K435 Coil Adapter must be used).

1.Open the Wire Drive Compartment Door

2.Depress the Release Bar on the Retaining Collar and remove it from the spindle.

3.Place the spool on the spindle making certain the spindle brake pin enters one of the holes in the back side of the spool (Note: an arrow mark on the spindle lines up with the brake holding pin to assist in lining up a hole). Be certain the wire comes off the reel in a direction so as to de-reel from the top of the coil.

4.Re-install the Retaining Collar. Make sure that the Release Bar “pops up” and that the collar retainers fully engage the retaining ring groove on the spindle.

TO START THE WELDER

Turn the “Power Switch” switch to “ON”. This lights the red LED dis- play lights. With the desired voltage and wire speed selected, oper- ate the gun trigger for welder output and to energize the wire feed motor.

POWER MIG 200

Image 16
Contents Power MIG Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill ARC Rays can burnCylinder may explode if damaged IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation SectionInstallation Technical Specifications Power MIG3INSTALLATIONA-3 Figure A.1 Dual Voltage Machine Input Connections Output Polarity Connections Figure A.2 Triple Voltage Machine Input ConnectionsShielding GAS GUN and Cable InstallationCylinder may explode if damaged Operation Section Operation Section BOperation Wear eye, ear and body protec- tionWire Drive Roll Wire Size Conversion PartsProduct Description Recommended Processes and EquipmentWire Reel Loading READI-REELS, Spools or Coils Procedure for Changing Drive and Idle Roll SetsTo Start the Welder Feeding Wire Electrode Making a Weld Idle Roll Pressure SettingAvoiding Wire Feeding Problems Wire Feed Overload ProtectionFAN Control Input Line Voltage VariationsAccessories Section Accessories Drive Roll KitsK363P READI-REEL Adapter Dual Cylinder Mounting KIT K1702-1Installed Adapter KIT and Spool GUNPower MIG Maintenance Section Maintenance Cause poor wire feeding Liner Removal and REPLACE- MentThis screw should only be gently tightened Overtightening will split or collapse the linerGUN Handle Disassembly English Metric Description SizeMaintenance Power MIG Line Switch Theory of Operation SectionTheory of Operation Output Rectification Contactor and Control Board Motor Control BoardControl BOARD, GUN Trigger and Wire Drive Motor Figure E.4 Optional CircuitsWirefeed Overload Protection Thermal and Overload ProtectionPower MIG Troubleshooting and Repair Section Troubleshooting and Repair Section FTroubleshooting and Repair How To Use Troubleshooting GuidePC Board Troubleshooting Procedures Perform the Main Transformer Perform the Output Contactor Avoid contact with any portion These capacitors is toxicYour body Function Problems Tachometer Feedback Test Welding Problems Weld bead is narrow or ropy Make sure the welding proce Test Description Main Transformer TestMaterials Needed ON/OFF Power Switch will be hot during these tests Main Transformer TestX10 Table F.1. Test Points Input Voltage Test PointsWire Drive Motor and Tachometer Feedback Test Test Procedure Figure F.4. Plug J4Disconnect the main AC input power to the machine Test for Supply Voltage to TachometerTest for Feedback Voltage to Control Board VDCOutput Bridge Rectifier Test Test Procedure Output Bridge Rectifier TestContactor Test Contactor Test Figure F.7. Contactor Terminals and LeadsVolts 10.0 Typical Output Voltage Waveform Machine Loaded MAX TAP GVolts 20.0 Normal Open Circuit Voltage Waveform MAX TAP GMachine Loaded to 180 Amps AT 16 VDC Scope Settings Volts 20.0 Control Board Replacement DescriptionControl Board Replacement ProcedureWire Drive Motor Assembly Replacement Wire Drive Motor Assembly Replacement Wire DriveBolt Gas Hose TOC Output Diode Bridge Rectifier Replacement Output Diode Bridge Rectifier Mounting Bracket Mounting Bolts Rectifier Power MIG Output Capacitors Replacement Output Capacitors Replacement Figure F.14. Capacitor Bank LocationLead Mounting Bolts Nuts & Lock washers Places Power MIG 41TROUBLESHOOTING and REPAIRF-41 Main Transformer ReplacementMain Transformer Replacement See Figure F.17Replacement Figure F.17. Leads X9, X10, 104B,104C, & H1BX2 X3 X4 X5 X6 X7 Lead Power MIG FAN BLADE/MOTOR Replacement FAN BLADE/MOTOR Replacement Perform the Output Capacitor Bank Removal ProcedureOutput Contactor Replacement Output Contactor Replacement Figure F.24Mounting Bolts Retest After Repair Electrical Diagrams Table of Contents Electrical Diagrams SectionPower MIG 200 208/230V Wiring DiagramSchematic Control PC Board PC Board ASSEMBLY-CONTROL G3851-1SVM Error Reporting Form