OVERLOAD PROTECTION
The power source is thermostatically protected with proximity thermostats against overload or insufficient cooling. One thermostat is located on the nose of the center bottom primary coil and a second thermostat is attached to the lead connecting the secondaries. Both thermostats are connected in series with
The power source is also protected against overloads on the SCR bridge assembly through the solid state fault protection circuit. This circuit senses an overload on the power source and limits the output to approxi- mately 550 amps by phasing back the SCR’s.
Protection is provided to protect the circuitry from acci- dental grounds. If leads 75, 76, or 77 are accidentally “grounded” to the positive output lead, the output will be reduced to a low value, thus preventing any damage to the machine. If the ground occurs between 75, 76, 77 and the negative output lead, one of the PC board elec- tronic
AUXILIARY POWER
On machines above code 9400, the IDEALARC CV- 400 can provide nominally 115 volts AC and 42 volts AC auxiliary power for operating wire feeding equip- ment and other accessories. This power is available at the
FRONT VIEW OF
RECEPTACLE
| K=42 |
A=32 | J=31 |
B=GND | I=41 |
L | N |
C=2 | H=21 |
D=4 | G=75 |
E=77 | F=76 |
| M |
PIN | LEAD NO. | FUNCTION |
A | 32 | 115 VAC |
B | GND | Chassis Connection |
C | 2 | Trigger Circuit |
D | 4 | Trigger Circuit |
E | 77 | Output Control |
F | 76 | Output Control |
G | 75 | Output Control |
H | 21 | Work Connection |
I | 41 | 42 VAC |
J | 31 | 115 VAC |
K | 42 | 42 VAC |
L | ||
M | ||
N | ||
|
|
|