CONNECTING THE LN-8 OR LN-9 TO THE IDEALARC CV-400

1.Set the CV-400 POWER toggle switch to the OFF (0) position.

2.Disconnect main AC input power to the CV-400.

3.Connect the wire feeder control cable leads to the CV-400 terminal strip as shown in Figure C.5.

4.Connect the wire feeder control cable ground lead

to the frame terminal marked .

5.Extend wire feeder control cable lead #21 so it can be connected directly to the work piece.

a.Make a bolted connection using AWG #14 or larger insulated wire. Tape the bolted connection with insulating tape.

b.An S-16586- X remote voltage sensing work lead is available for this purpose.

c.Keep the #21 lead electrically separate from the work cable circuit and connection.

d.Tape the #21 lead to the work cable for ease of use.

NOTE: Using the extended #21 lead eliminates the need to use the LN-9's remote work lead accesso- ry, which has a direct work lead jack.

6.Connect the LN-9 wire feeder control jumpers on the Voltage Control board. See LN-9 operator's manual.

NOTE: The connection diagram shown in Figure C.5 shows the electrode connected for positive polarity. To change polarity:

a.Set the CV-400 POWER toggle switch to the OFF

(0) position.

b.Move the electrode cable to the negative (-) out- put terminal.

c.Move the work cable to the positive (+) output terminal.

d.Set the VOLTMETER toggle switch on power source to negative (-).

e.Set the voltmeter toggle switch on feeder (if equipped) to match electrode polarity.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

FIGURE C.5

LN-8 OR LN-9 WIRE FEEDER CONNECTION TO THE IDEALARC CV-400

LN-8 ORLN-9

TERMINAL

WIRE FEEDER

CONTROL CABLE

STRIPS

TO

21

 

INPUT

 

CABLE

4

 

 

 

GND

2

 

21

BLANK

 

4

31

 

2

 

32

 

31

 

 

32

75

 

 

 

75

76

 

77

 

76

 

 

 

77

 

 

 

-

+

 

NEGATIVE

POSITIVE

 

 

ELECTRODE

 

TO

CABLE TO

 

AUTOMATIC

 

WORK

 

EQUIPMENT

 

 

IDEALARC CV-400

Image 29
Contents Idealarc CV-400 California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéMaster Table of Contents for ALL Sections Table of Contents Installation Section Technical Specifications Idealarc CV-400 InstallationLifting Safety PrecautionsLocation and Ventilation Input Supply Connections Ground ConnectionReturn to Input Wire and Fuse SizeConnect Electrode and Work Leads to Output Terminals Reconnect Procedure Output ConnectionsFigure A.5 Output Terminal Connections Connect Wire Feeders Table of Contents Operation Section Operating Instructions Safety InstructionsOperation Design Features Operational Features and ControlsGeneral Description Recommended ProcessesLimitations Welding CapabilityFigure B.1 Case Front Controls Controls and SettingsLocal Control Remote ControlWelding Operation Overload Protection Auxiliary PowerIdealarc CV-400 Table of Contents Accessories Field Installed Options OPTIONS/ACCESSORIESFactory Installed Options Connecting the NA-3 to the Idealarc CV-400 Automatic Wire FeedersFeederterminal Connecting the NA-5 to the Idealarc CV-400Accessories Connecting the LN-7 to the Idealarc CV-400 Terminal Strip Semiautomatic Wire FeedersConnecting the LN-8 or LN-9 to the Idealarc CV-400 Idealarc CV-400 Table of Contents Maintenance Return to Return to Section TOC Safety Precautions Routine and Periodic MaintenanceFigure D.1 Idealarc CV-400 Table of Contents Theory of Operation Section Input Line VOLTAGE, Contactor and Main Transformer Theory of OperationOutput CONTROL, Rectification and Feedback Figure E.4 CV-400 Trigger and Thermal Light Circuit Protective Devices CircuitsFigure E.5 SCR Operation SCR OperationIdealarc CV-400 Table of Contents Troubleshooting & Repair Section HOW to USE Troubleshooting Guide Troubleshooting & RepairElectric Shock can kill PC Board Troubleshooting ProceduresOutput Problems Troubleshooting GuideOutput Problems SCR/Diode Perform the SCR/Diode Bridge SCR/Diode Rectifier Bridge Test Welding Problems Materials Needed Control Transformer T2 Voltage TestDescription Control Transformer T2 Voltage Test Test ProcedureRight Side View Input Contactor Test Input Contactor Test Figure F.4 Input Contactor Test Connections Test for Contact ContinuityMain Transformer T1 Voltage Test Main Transformer T1 Voltage Test Figure F.6 Main Secondary Lead Test Points Blank Main Transformer T1 Voltage Test Static SCR/DIODE Rectifier Bridge Test Static SCR/DIODE Rectifier Bridge Test SCR Anode Remove ANY Insulating Paint Cathode SCR Active SCR Test Active SCR Test Figure F.15 Heat Sink Test Points Figure F.16 SCR Tester Circuit and SCR Connections Normal Open Circuit Voltage Waveform Maximum Output Setting no LoadTypical Output Voltage Waveform Machine Loaded Typical SCR Gate Voltage Waveform Maximum Output Setting no LoadONE Output SCR not Functioning Abnormal Output Voltage Waveform Machine LoadedDescription Input Contactor CR1 CLEANING/REPLACEMENTContactor Replacement Procedure Cleaning ProcedureFAN Motor and Blade Removal and Replacement Procedure FAN Motor and Blade Removal and ReplacementSCR/DIODE Rectifier Assembly Removal and Replacement Removal and Replacement SCR/DIODE Rectifier AssemblySCR Removal and Replacement SCR Removal and Replacement Figure F.21 1/2 Wide Leaf Spring Procedure for the 1/2 Inch Wide SpringClamping Procedure For 1/4-20 CAP Screws Clamping Procedure For 1/4-28 CAP ScrewsInch Wide Spring Procedure forAfter Replacing the SCRs Mounting of Stud Type Diodes To Aluminum Heat Sinks To Aluminum Heat Sinks Mounting of Stud Type DiodesMain Transformer Removal and Replacement Removal of Lift Bail Main Transformer Removal & ReplacementFigure F.26 Choke Removal Removal of Choke and TOP Iron AssemblyFigure F.27 Epoxy MIX Application Areas Reassembly of Transformer CoilsFigure F.28 Coil Lead Placement Figure F.30 Primary Thermostat Location Reassemble the Lift Bail Reassembling the Main Transformer Into the MachineInput Idle Amps and Watts Retest After RepairOpen Circuit Voltages Welding Output Load TestIdealarc CV-400 Section G Electrical DiagramsWiring Diagram Codes 10084, 10085 Wiring Diagram Code Control PC Board G2629-1 Layout Control PC Board G2629-1 Schematic Snubber Snubber PC Board M15370-3 Schematic Idealarc CV-400