| INSTALLATION |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TABLE lll |
|
|
|
|
|
|
| ELECTRICAL DEVICE USE WITH THE RANGER® 305LPG. |
|
| ||
|
|
|
|
|
|
|
| |
|
| Type |
| Common Electrical Devices | Possible Concerns |
|
| |
|
|
|
|
|
|
|
| |
|
| Resistive |
| Heaters, toasters, incandescent | NONE |
|
| |
|
|
|
|
| light bulbs, electric range, hot |
|
|
|
|
|
|
|
| pan, skillet, coffee maker. |
|
|
|
|
|
|
|
|
|
|
| |
|
| Capacitive |
| TV sets, radios, microwaves, | Voltage spikes or high voltage |
|
| |
|
|
|
|
| appliances with electrical control. | regulation can cause the capaci- |
|
|
|
|
|
|
|
| tative elements to fail. Surge |
|
|
|
|
|
|
|
| protection, transient protection, |
|
|
|
|
|
|
|
| and additional loading is recom- |
|
|
|
|
|
|
|
| mended for 100% |
|
|
|
|
|
|
|
| ation. DO NOT RUN THESE |
|
|
|
|
|
|
|
| DEVICES WITHOUT ADDI- |
|
|
|
|
|
|
|
| TIONAL RESISTIVE TYPE |
|
|
|
|
|
|
|
| LOADS. |
|
|
|
|
|
|
|
|
|
| |
|
| Inductive |
| These devices require large |
|
| ||
|
|
|
|
| drills, well pumps, grinders, small | current inrush for starting. |
|
|
|
|
|
|
| refrigerators, weed and hedge | Some synchronous motors may |
|
|
|
|
|
|
| trimmers | be frequency sensitive to attain |
|
|
|
|
|
|
|
| maximum output torque, but |
|
|
|
|
|
|
|
| they SHOULD BE SAFE from |
|
|
|
|
|
|
|
| any frequency induced failures. |
|
|
|
|
|
|
|
|
|
| |
|
| Capacitive/Inductive |
| Computers, high resolution TV sets, | An inductive type line condition- |
|
| |
|
|
|
|
| complicated electrical equipment. | er along with transient and |
|
|
|
|
|
|
|
| surge protection is required, and |
|
|
|
|
|
|
|
| liabilities still exist. DO NOT |
|
|
|
|
|
|
|
| USE THESE DEVICES WITH A |
|
|
|
|
|
|
|
| RANGER® 305LPG. |
|
|
|
|
|
|
|
|
|
|
|
The Lincoln Electric Company is not responsible for any damage to electrical components improperly connected to the RANGER® 305LPG.
RANGER® 305LPG