b-5

OPERATION

b-5

 

 

 

TIG WELDING

The TOUCH START TIG setting of the MODE switch is for DC TIG (Tungsten Inert Gas) welding. To initiate a weld, the CONTROL dial is first set to the desired current and the tung- sten is touched to the work. During the time the tungsten is touching the work there is very little voltage or current and in general, no tungsten contamination. Then, the tungsten is gently lifted off the work in a rocking motion, which establish- es the arc.

The ARC CONTROL is not active in the TIG mode. To STOP a weld, simply pull the TIG torch away from the work. When the arc voltage reaches approximately 30 Volts the arc will go out and the machine will reset the current to the Touch Start level. To reinitiate the arc, re touch the tungsten to the work and lift. Alternatively, the weld can be stopped by releasing the Amptrol or arc start switch.

The RANGER® 305LPG can be used in a wide variety of DC TIG welding applications. In general the ‘Touch Start’ feature allows contamination free starting without the use of a Hi-fre- quency unit. If desired, the K930-2 TIG Module can be used with the RANGER® 305LPG. The settings are for reference.

RANGER® 305LPG settings when using the K930-2 TIG Module with an Amptrol or Arc Start Switch:

Set the MODE Switch to the TOUCH START TIG setting.

Set the "IDLER" Switch to the "AUTO" position.

Set the "WELDING TERMINALS" switch to the "REMOTE- LY CONTROLLED" position. This will keep the "Solid State" contactor open and provide a “cold” electrode until the Amptrol or Arc Start Switch is pressed.

When using the TIG Module, the OUTPUT control on the RANGER® 305LPG is used to set the maximum range of the CURRENT CONTROL on the TIG module or an Amptrol if connected to the TIG Module.

WIRE WELDING-CV

Connect a wire feeder to the RANGER® 305LPG according to the instructions in INSTALLATION INSTRUCTIONS Section.

The RANGER® 305LPG in the CV-WIRE mode, permits it to be used with a broad range of flux cored wire (Innershield and outreached) electrodes and solid wires for MIG welding (gas metal arc welding). Welding can be finely tuned using the ARC CONTROL. Turning the ARC CONTROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance con- trol. The proper setting depends on the procedure and oper- ator preference. Start with the dial set at 0.

Listed below are some wires suitable for use on this machine:

Innershield - NR-311, NS-3M, NR-207, NR-203 Ni 1%, NR-212.

outreached - 0S-70, 0S-71M, 0S-71 ELITE.

Solid wires for MIG welding - .035 (0.9 mm), and

.045 (1.1 mm), Super Arc L-50 and L-56, .035 (0.9 mm) and

.045 (1.1 mm) Blue Max MIG 308 lw.

Contact your local authorized Lincoln Electric Distributor or the Lincoln Electric Company for specific wires used on certain applications with this machine.

TYPICAL CURRENT RANGES (1) FOR TUNGSTEN ELECTRODES(2)

Tungsten Electrode

DDENE (-)

DAzE (+)

Approximate Argon Gas Flow

 

TIG TORCH

Diameter in. (mm)

 

 

Flow Rate C.F.H. ( l /min.)

 

 

Nozzle Size (4), (5)

 

 

1%, 2% Thoriated

1%, 2% Thoriated

Aluminum

 

Stainless Steel

 

 

 

Tungsten

Tungsten

 

 

 

 

 

 

.010

(.25)

2-15

(3)

3-8

(2-4)

 

3-8

(2-4)

#4, #5, #6

0.020

(.50)

5-20

(3)

5-10

(3-5)

 

5-10

(3-5)

 

0.040

(1.0)

15-80

(3)

5-10

(3-5)

 

5-10

(3-5)

 

1/16

(1.6)

70-150

10-20

5-10

(3-5)

 

9-13

(4-6)

#5, #6

3/32

(2.4)

150-250

15-30

13-17

(6-8)

 

11-15

(5-7)

#6, #7, #8

1/8

(3.2)

250-400

25-40

15-23

(7-11)

 

11-15

(5-7)

 

5/32

(4.0)

400-500

40-55

21-25

(10-12)

 

13-17

(6-8)

#8, #10

3/16

(4.8)

500-750

55-80

23-27

(11-13)

 

18-22

(8-10)

 

1/4

(6.4)

750-1000

80-125

28-32

(13-15)

 

23-27

(11-13)

 

 

 

 

 

 

 

 

 

 

 

(1)When used with argon gas. The current ranges shown must be reduced when using argon/helium or pure helium shielding gases.

(2)Tungsten electrodes are classified as follows by the American Welding Society (AWS):

Pure

EWP

1% Thoriated

Esther

2% Thoriated

Esther

Though not yet recognized by the AWS, Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated Tungsten in AC and DC applications.

(3)DAzE is not commonly used in these sizes.

(4)TIG torch nozzle "sizes" are in multiples of thus of an inch:

# 4 = 1/4 in.

(6 mm)

# 5

= 5/16 in.

(8 mm)

# 6

= 3/8 in.

(10 mm)

# 7

= 7/16 in.

(11 mm)

# 8

= _ in.

(12.5 mm)

#10 = 5/8 in.

(16 mm)

(5)TIG torch nozzles are typically made from alumina ceramic. Special applications may require lava nozzles, which are less prone to breakage, but cannot withstand high tem- peratures and high duty cycles.

RANGER® 305LPG

Image 24
Contents Safety Depends on You RangerSafety For EngineElectric Magnetic Fields Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTAbLE of Contents Vii Section DSection E Section FInstallation Technical Specifications Ranger 305LPG K2937-1Auxiliary Power Circuit bREAKER Other Circuit bREAKERS ReceptaclesSafety Precautions Additional Safety PrecautionsLocation and Ventilation High Altitude OperationPRE-OPERATION Service FuelVehicle Mounting Tighten by handElectrical Connections CAbLE Installation Total COMbINED Length of Electrode and Work CAbLESWelding Terminals Welding Output CAbLESElectrical Device USE with the Ranger 305LPG Type Common Electrical Devices Possible ConcernsAuxiliary Power Receptacles STANDbY Power ConnectionsConnection of Ranger 305LPG to Premises Connection of Lincoln Electric Wire Feeders Connection of LN-7 or LN-8 to the Ranger 305LPGConnection of LN-15 to the Ranger 305LPG Across The-Arc Model11INSTALLATIONA-11 For Auxiliary Power OperationGeneral Description Engine OperationWeld Mode Selector Switch Welding ControlsOutput Control Digital Output MetersEngine Controls Welder Operation Wire WELDING-CV TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Auxiliary Power ARC GougingRanger 305LPG Extension Cord Length Recommendations Accessories Maintenance Engine Maintenance ComponentsKohler Engine FrequencyEngine Oil Refill Capacities Without oil filter replacement Air Cleaner ServiceEngine Oil Change Oil Filter ChangeSpark Plug Service Spark PlugAIR Filter Paper Element Engine Adjustment Servicing Optional Spark ArrestorChecking the Electrolyte Level Welder/Generator Maintenance Gfci Receptacle Testing and RESET- Ting ProcedureTROUbLESHOOTING PRObLEMS SymptomsIs Evident.Authorized Field Service Facility POSSIbLEAuthorized Field Service Facility Contact your local LincolnFaulty control cable. Repair or Stick Sive voltage dropDiagrams Diagrams Diagrams Diagrams Diagrams Engine Welders /LN-8 Connection Diagram S24787-6Diagrams Diagrams Diagrams Diagrams Diagrams Dimension PrintRanger 305LPG Ranger 305LPG Precaucion Guards off