Lincoln Electric IM648-B specifications Operation, Safety Precautions, Description

Page 14

B-1

OPERATION

B-1

 

 

 

Read and understand this entire section before oper- ating the machine.

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground.

Always wear dry insulating gloves.

FUMES AND GASES

can be dangerous.

• Keep your head out of fumes.

Use ventilation or exhaust to remove fumes from breathing zone.

WELDING, CUTTING and

GOUGING SPARKS

can cause fire or explosion

Keep flammable material away.

Do not weld, cut or gouge on containers that have held combustibles.

ARC RAYS can burn.

Wear eye, ear and body protection.

PLASMA ARC can injure

Keep your body away from nozzle and plasma arc.

Operate the pilot arc with caution. The pilot arc is capable of burning the operator, others or even piercing safety clothing.

Observe additional Safety Guidelines detailed in the beginning of this manual.

NOTE: All P.C. boards are protected by a moisture resistant coating. When the plasma cutter is operated, this coating will "bake off" of certain power resistors that normally oper- ate at high temperatures emitting some smoke and odor for a short time. These resistors and the P.C. board beneath them may become darkened. This is a normal occurrence and does not damage the component or affect the machine

performance.

DESCRIPTION

The PYTHON is a constant current, continuous con- trol plasma cutting power source. It provides superior and reliable starting characteristics, cutting visibility and arc stability. When cutting expanded metal, the PYTHON out performs the competition due to its quick, clean response to arc transfers. The power supply design provides high transfer-to-cut distances which makes pierce cutting more reliable and with less nozzle wear. The control system has a safety mechanism to insure that the nozzle and electrode are in place before cutting or gouging. This is extremely important due to the high voltages involved.

The PYTHON comes standard with an air regulator, coarse air filter, and pressure gauge. There are six dif- ferent torch and cable systems to choose from: hand- held torch with 25' or 50' cable, machine and robotic torch both with 25' and 50' cable. Consumables are included so that cutting can begin right out of the box. Consumables can also be ordered as individual pack- ages.

The PYTHON initiates the plasma arc with a simple, yet reliable, touch start mechanism. This system elimi- nates many of the failure problems associated with hi- frequency start systems. The PYTHON is capable of cutting with nitrogen or air.

The PYTHON is controlled by a microprocessor- based control board. The machine performs rudimen- tary self troubleshooting when powered up which aids in field servicing.

PREHEAT TEMPERATURE FOR PLASMA CUTTING

Preheat temperature control is not necessary in most applications when plasma arc cutting or gouging. Preheat temperature control may be necessary on high carbon alloy steels and heat treated aluminum for crack resistance and hardness control. Job conditions, pre- vailing codes, alloy level, and other considerations may also require preheat temperature control. The following minimum preheat temperature is recommended as a starting point. Higher temperatures may be used as required by the job conditions and/or prevailing codes. If cracking or excessive hardness occurs on the cut face, higher preheat temperature may be required. The recommended minimum preheat temperature for plate thickness up to 1/2" (12.7mm) is 70°F (21.1°C).

PYTHON

Image 14
Contents RED-D-ARC Python Safety Electric Shock can killPlasma ARC can injure Iii Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Vii Installation Three Phase Single PhaseHigh Frequency Interference Protection Safety Precautions Electric Shock can KillSelect Proper Location Input Electrical Connections Power Input ConnectionInput Power Cord Connector Installation Frame Grounding Input Voltage Reconnection ProcedureUSE on Engine Driven Power Supplies GAS Input Connections Output ConnectionsOperation Safety PrecautionsPreheat Temperature for Plasma Cutting DescriptionUser Responsibility Operational Features and ControlsDesign Features Advantages Recommended Processes and EquipmentCutting Capability Consumable LifeControls and Settings LimitationsSafety LED Thick Sections of Metal Procedure RecommendationsPilot ARC Discussion ARC Initiated Machine InterfaceARC Start ARC VoltageAccessories General Options AccessoriesMaintenance Input Filter Capacitor Discharge ProcedureRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideYour local Lincoln Authorized Field Service Facility Python powers up properly 1. Press Purge button on the front Possible fault in Output Power board Or dross Symptom Check Wiring Diagram Python Code Diagrams Shown for 400-460VAC Operation Slow BlowWiring Diagram for Code Wiring Diagram for Code Dimension Print Python Precaucion Warnung