Lincoln Electric IM648-B specifications Your local Lincoln Authorized Field Service Facility

Page 25

E-2

TROUBLESHOOTING

E-2

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

No Status indicators light and the fan 1. Check the input power to be sure does not operate 5 seconds after the it is on.

power switch is turned on.

2. Check the power line fuses and machine connection.

3. Disconnect input power at fuse panel and check line switch conti- nuity. Replace line switch if bad.

4. Auxiliary transformer may be faulty.

No Status indicators light 5 seconds 1. Auxiliary transformer may be after the power switch is turned on, faulty.

but the fan operates.

2. Disconnect input power from the machine. Check that connectors on harness between Control Bd. and Display Bd. are properly seat- ed.

3. Possible faulty Control Board.

All Status indicators remain lit imme- 1. The microprocessor has experi-

diately after power up.enced a memory fault. Consult local Lincoln Field Service shop.

All Status indicators begin to blink 1. Turn power off. Make sure recon-

within 5 seconds after power up.

nect is positioned correctly for the

(Overvoltage Protection has been

input voltage used. Wait at least 1

activitated)

minute after power down before

 

re-connecting the machine.

 

Reconnect machine,then restore

 

power to PYTHON.

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact

your local Lincoln Authorized Field Service Facility.

2.Possible faulty Primary board.

3.Possible faulty Control board.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

PYTHON

Image 25
Contents RED-D-ARC Python Electric Shock can kill SafetyPlasma ARC can injure Iii Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Vii Three Phase Single Phase InstallationSelect Proper Location Safety Precautions Electric Shock can KillHigh Frequency Interference Protection Input Power Cord Connector Installation Power Input ConnectionInput Electrical Connections USE on Engine Driven Power Supplies Input Voltage Reconnection ProcedureFrame Grounding Output Connections GAS Input ConnectionsPreheat Temperature for Plasma Cutting Safety PrecautionsOperation DescriptionDesign Features Advantages Operational Features and ControlsUser Responsibility Recommended Processes and EquipmentConsumable Life Cutting CapabilityLimitations Controls and SettingsSafety LED Pilot ARC Discussion Procedure RecommendationsThick Sections of Metal ARC Start Machine InterfaceARC Initiated ARC VoltageGeneral Options Accessories Accessories Input Filter Capacitor Discharge Procedure MaintenancePeriodic Maintenance Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingYour local Lincoln Authorized Field Service Facility Python powers up properly 1. Press Purge button on the front Possible fault in Output Power board Or dross Symptom Check Wiring Diagram Python Code Shown for 400-460VAC Operation Slow Blow DiagramsWiring Diagram for Code Wiring Diagram for Code Dimension Print Python Precaucion Warnung