The PYTHON is rated at 80 amps, at 60% duty cycle on a 10 minute basis or 60 amps, at 100% duty cycle. If the duty cycle is exceeded, a thermal protector will shut off the output of the machine until it cools to the normal oper- ating temperature.

Figure B.1 shows the cut capacity of the PYTHON when cutting mild steel. The graph plots cut thickness vs. torch travel speed with a torch standoff of 0.15". Example: 0.5” material may be cut at a setting of 55 amps at an approximate speed of 25 IPM or at a setting of 80 amps at an approximate speed of 35 IPM.

Recommended Torch Travel Speed (IPM)

 

100

 

 

 

Speed

80

 

60

 

Maximum

 

40

 

80% of

20

 

 

 

 

0

 

 

 

 

0.000

PYTHON

Mild Steel Cut Capacity Chart

 

 

 

25 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35 A

 

 

 

55 A

 

80 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.125

0.250

0.375

0.500

0.625

0.750

1.00

Material Thickness

Figure B.1

CONSUMABLE LIFE

The expected life for the PYTHON's electrode under normal operating conditions is approximately 160 starts/cuts. An erosion of .060" is typical for end of electrode life, however, the electrode life may last longer. A green and erratic arc will indicate definite electrode failure and the electrode should be replaced immediately.

It is recommended that consumables be replaced in complete sets. (Example: Electrode and Nozzle). This will maximize the performance of the PYTHON system.

PYTHON

Image 16
Contents RED-D-ARC Python Safety Electric Shock can killPlasma ARC can injure Iii Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Vii Installation Three Phase Single PhaseSelect Proper Location Safety Precautions Electric Shock can KillHigh Frequency Interference Protection Input Power Cord Connector Installation Power Input ConnectionInput Electrical Connections USE on Engine Driven Power Supplies Input Voltage Reconnection ProcedureFrame Grounding GAS Input Connections Output ConnectionsSafety Precautions Preheat Temperature for Plasma CuttingOperation DescriptionOperational Features and Controls Design Features AdvantagesUser Responsibility Recommended Processes and EquipmentCutting Capability Consumable LifeControls and Settings LimitationsSafety LED Pilot ARC Discussion Procedure RecommendationsThick Sections of Metal Machine Interface ARC StartARC Initiated ARC VoltageAccessories General Options AccessoriesMaintenance Input Filter Capacitor Discharge ProcedureRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideYour local Lincoln Authorized Field Service Facility Python powers up properly 1. Press Purge button on the front Possible fault in Output Power board Or dross Symptom Check Wiring Diagram Python Code Diagrams Shown for 400-460VAC Operation Slow BlowWiring Diagram for Code Wiring Diagram for Code Dimension Print Python Precaucion Warnung