Lincoln Electric IM648-B specifications Symptom Check

Page 29

E-6

 

TROUBLESHOOTING

E-6

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

STATUS BOARD INDICATORS

 

 

 

 

 

 

 

 

 

 

SYMPTOM

 

 

 

 

CHECK

 

 

 

 

 

 

Machine is unresponsive immediately after

1.

There is a 4 second soft start period for pre-charging the input fil-

power-up.

 

 

ter capacitors. Wait until that time is up. The Power LED will light

 

 

 

 

when ready. If not, refer to the first part of this section.

 

 

 

 

 

 

 

The Air Low LED is lit

 

1.

Make sure there is at least 80 psi connected to the gas connec-

 

 

 

 

tion at the back of the machine.

 

 

 

 

2.

Press the Purge button and set the regulator to 70 psi (75 psi for

 

 

 

 

a 50 ft. torch). The pressure may increase when air stops flowing

 

 

 

 

but this is normal. Do not reset the pressure while the air is OFF.

 

 

 

3.

Possible faulty Pressure Switch.

 

 

 

 

4.

Possible faulty Control board.

 

 

 

 

 

 

 

The Safety LED is flashing

 

1.

Make sure there is a Lincoln torch and cable assembly connect-

 

 

 

 

ed properly to the PYTHON bulk head connector.

 

 

 

 

2.

Check consumables for proper installation or excessive wear.

 

 

 

 

Replace if excessively worn. If not, use a piece of fine emery

 

 

 

 

cloth to remove any oxide buildup on the tip of the electrode.

 

 

 

 

 

 

 

The Safety LED is lit and steady

 

1.

Press the Reset button. If torch and consumables are properly

 

 

 

 

installed, the Safety LED should turn off. Normal cutting or goug-

 

 

 

 

ing can resume.

 

 

 

 

 

 

 

The Thermal LED is lit

 

1.

The machine's thermostat has tripped due to exceeded duty

 

 

 

 

cycle limits. Do NOT turn the power off. Allow the machine to

 

 

 

 

cool for 15 - 30 minutes and the thermostat will reset itself.

 

 

 

 

2.

The machine's air louvers or fans are obstructed such that air

 

 

 

 

cannot flow to properly cool the machine. Remove any foreign

 

 

 

 

material that may block air flow. Blow the machine out with a

 

 

 

 

clean, dry air stream.

 

 

 

 

3.

Possible faulty Control board.

 

 

 

 

 

 

The Ready, Air Lowand ThermalLEDs

1.

This is typically caused by connecting the auxiliary transformer

are flashing

 

 

input tap to the wrong voltage. Turn machine OFF and change

 

 

lead to correct input voltage at reconnect panel.

 

 

 

 

 

 

 

 

 

2.

Possible faulty Control P. C. Board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PYTHON

Image 29
Contents RED-D-ARC Python Electric Shock can kill SafetyPlasma ARC can injure Iii Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Vii Three Phase Single Phase InstallationHigh Frequency Interference Protection Safety Precautions Electric Shock can KillSelect Proper Location Input Electrical Connections Power Input ConnectionInput Power Cord Connector Installation Frame Grounding Input Voltage Reconnection ProcedureUSE on Engine Driven Power Supplies Output Connections GAS Input ConnectionsPreheat Temperature for Plasma Cutting Safety PrecautionsOperation DescriptionDesign Features Advantages Operational Features and ControlsUser Responsibility Recommended Processes and EquipmentConsumable Life Cutting CapabilityLimitations Controls and SettingsSafety LED Thick Sections of Metal Procedure RecommendationsPilot ARC Discussion ARC Start Machine InterfaceARC Initiated ARC VoltageGeneral Options Accessories AccessoriesInput Filter Capacitor Discharge Procedure MaintenancePeriodic Maintenance Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingYour local Lincoln Authorized Field Service Facility Python powers up properly 1. Press Purge button on the front Possible fault in Output Power board Or dross Symptom Check Wiring Diagram Python Code Shown for 400-460VAC Operation Slow Blow DiagramsWiring Diagram for Code Wiring Diagram for Code Dimension Print Python Precaucion Warnung