Lincoln Electric IM648-B specifications Maintenance, Input Filter Capacitor Discharge Procedure

Page 22

D-1

MAINTENANCE

D-1

 

 

 

WARNING

ELECTRIC SHOCK can kill.

Have an electrician install and service this equipment.

Turn the input power off at the fuse box before working on equipment.

Do not touch electrically hot parts.

Prior to Performing preventative main- tenance, perform the following capaci- tor discharge procedure to avoid elec- tric shock.

---------------------------------------------------------------------

INPUT FILTER CAPACITOR

DISCHARGE PROCEDURE

1.Turn off input power or disconnect input power lines.

2.Remove the 5/16" hex head screws from the side and top of the machine and remove wrap-around machine cover.

3.Be careful not to make contact with the capacitor terminals that are located on the top and bottom of the Power Board on the right side of the machine.

4.Obtain a high resistance and high wattage resistor (25-1000 ohms and 25 watts minimum). This resis- tor is not supplied with machine. NEVER USE A SHORTING STRAP FOR THIS PROCEDURE.

5.Locate the two capacitor terminals (large hex head cap screws) on the Power P.C. Board shown in Figure D.1.

6.Use electrically insulated gloves and insulated pli- ers. Hold body of the resistor and connect resistor leads across the two capacitor terminals. Hold resistor in place for 10 seconds. DO NOT TOUCH CAPACITOR TERMINALS WITH YOUR BARE HANDS.

7.Repeat discharge procedure for the other capaci- tor .

8.Check voltage across terminals of all capacitors with a DC voltmeter. Polarity of capacitor terminals is marked on PC board above terminals. Voltage should be zero. If any voltage remains, repeat this capacitor discharge procedure.

FIGURE D.1 — LOCATION OF INPUT FILTER CAPACITOR TERMINALS.

POWER

BOARD

CAPACITOR

TERMINALS

POWER

RESISTOR

RIGHT SIDE OF MACHINE

INSULATED

 

PLIERS

INSULATED

GLOVES

PYTHON

Image 22
Contents RED-D-ARC Python Safety Electric Shock can killPlasma ARC can injure Iii Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Vii Installation Three Phase Single PhaseSelect Proper Location Safety Precautions Electric Shock can KillHigh Frequency Interference Protection Input Power Cord Connector Installation Power Input ConnectionInput Electrical Connections USE on Engine Driven Power Supplies Input Voltage Reconnection ProcedureFrame Grounding GAS Input Connections Output ConnectionsOperation Safety PrecautionsPreheat Temperature for Plasma Cutting DescriptionUser Responsibility Operational Features and ControlsDesign Features Advantages Recommended Processes and EquipmentCutting Capability Consumable LifeControls and Settings LimitationsSafety LED Pilot ARC Discussion Procedure RecommendationsThick Sections of Metal ARC Initiated Machine InterfaceARC Start ARC VoltageAccessories General Options AccessoriesMaintenance Input Filter Capacitor Discharge ProcedureRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideYour local Lincoln Authorized Field Service Facility Python powers up properly 1. Press Purge button on the front Possible fault in Output Power board Or dross Symptom Check Wiring Diagram Python Code Diagrams Shown for 400-460VAC Operation Slow BlowWiring Diagram for Code Wiring Diagram for Code Dimension Print Python Precaucion Warnung