| ROBOTIC INTERFACE | |||||
|
|
|
| |||
| 5. ROBOT CONTROLLER SETUP | 22 | Reset | DISABLED | ||
|
|
|
| 23 | Reset tries | 1 |
| 5.1 WELD SYSTEM SETUP |
| 24 | Voltage | 50.0V | |
|
| 25 | Time | 0.00s | ||
|
|
|
| VOLTAGE OUTPUT SCALING |
| |
| MONITORING FUNCTIONS |
| 26 | Minimum reference | 0.60V | |
1 | Arc loss | ENABLED | 27 | Maximum reference | 9.60V | |
2 | Gas shortage | DISABLED | 28 | Minimum output | 50.0V | |
3 | Wire shortage | DISABLED | 29 | Maximum output | 150.0V | |
4 | Wire stick | ENABLED | CURRENT OUTPUT SCALING |
| ||
5 | Power supply failure | ENABLED | 30 | Minimum reference | 0.00V | |
6 | Coolant shortage | ENABLED | 31 | Maximum reference | 10.00 | |
| WELD RESTART FUNCTION |
| 32 | Minimum output | 0.0A | |
7 | Return to path | DISABLED | 33 | Maximum output | 400.0A | |
8 | Overlap distance | 0mm | WIRE FEED SPEED OUTPUT SCALING | |||
9 | Return to path speed | 200mm/s | 34 | Minimum reference | 0.60V | |
| SCRATCH START FUNCTION |
| 35 | Maximum reference | 9.60V | |
10 | Scratch start | DISABLED | 36 | Minimum output | 50IPM | |
11 | Distance | 5mm | 37 | Maximum output | 770IPM | |
12 | Return to start speed | 12mm/s | VOLTAGE INPUT SCALING |
| ||
|
| 38 | Minimum reference | 0.0219V | ||
13 | ENABLED |
|
| R = 7.268 (7.620) | ||
14 | Voltage increment | 1.0V | 39 | Maximum reference | 7.289V | |
15 | Wire feed increment | 5.0IPM |
|
| ZERO ~ 0.020 | |
16 | Current increment | 5.0A | 40 | Minimum output | 0.0V | |
| OTHER FUNCTIONS |
| 41 | Maximum output | 80.0V | |
17 | Weld from teach pendent | ENABLED | CURRENT INPUT SCALING |
| ||
18 | Run in | DISABLED | 42 | Minimum reference | 0.7848V | |
19 | Wire burnback/retract | DISABLED |
|
| R = 8.32 (8.317) | |
|
|
|
| 43 | Maximum reference | 9.104V |
5.2 WELD EQUIPMENT SETUP
1 | Weld process | MIG |
2 | Remote arc enable | DI 0 |
3 | Weld power control | Wire FD |
4 | Wire feed control | AO |
5 | Wire+ Wire- speed | 80IPM |
6 | Wire feed speed units | IPM |
WELD RUN IN |
| |
7 | Voltage | 50.0V |
8 | Current | 250.0A |
9 | Wire feed | 200IPM |
10 | Time | 0.00s |
WIRE BURNBACK/RETRACT |
| |
11 | Voltage | 50.0V |
12 | Current | 250.0A |
13 | Wire feed | 0IPM |
14 | Time | 0.00s |
TIMING |
| |
15 | Arc start error time | 2.00s |
16 | Arc detect time | 0.10s |
17 | Arc loss error time | 0.30s |
18 | Gas detect time | 0.05s |
19 | Gas purge time | 1.00s |
20 | Gas preflow time | 0.50s |
21 | Gas postflow time | 0.00s |
WIRE STICK FUNCTION
|
| ZERO =0.58 - 0.80 |
44 | Minimum output | 0.0A |
45 | Maximum output | 750A |
5.3 | SYSTEM VARIABLES |
|
| $AWEUPR $WSTK_ENA_DLY 0.10s | |
5.4 | TOUCH SENSING SETUP |
|
| Sensor port type | WI |
| Sensor port number | 1 |
| Circuit port type | WO |
| Circuit port number | 3 |
POWER WAVE 450 | APR97 |
|