Lincoln Electric IM542-D manual Installation, Technical Specifications Power Wave, Awgiec

Page 11

A-1

 

 

INSTALLATION

 

 

 

 

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - THREE PHASE 50/60

HZ. ONLY

 

 

 

 

 

 

 

 

 

Input Voltages:

200

 

230

 

 

 

400

 

 

460

 

575

 

 

 

 

Input Currents

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@ 500A/40 VDC

87

 

76

 

 

 

44

 

 

38

 

32

 

 

 

 

@ 450A/38 VDC

75

 

65

 

 

 

38

 

 

32

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle

 

 

 

Amps

 

 

 

 

Volts at Rated Amperes

 

 

200 - 60% Duty Cycle

 

 

500

 

 

 

 

 

 

40 VDC

 

 

 

230/400/460 - 60% Duty Cycle

 

500

 

 

 

 

 

 

40 VDC

 

 

 

460/575 - 60% Duty Cycle

 

 

500

 

 

 

 

 

 

40 VDC

 

 

 

200 - 100% Duty Cycle

 

 

450

 

 

 

 

 

 

38 VDC

 

 

 

230/400/460 - 100% Duty Cycle

 

450

 

 

 

 

 

 

38 VDC

 

 

 

460/575 - 100% Duty Cycle

 

 

450

 

 

 

 

 

 

38 VDC

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

Constant Open

 

 

Continuous

 

 

 

Process

 

 

 

Circuit Voltage

 

 

Current Range

 

 

Current Ranges

 

 

 

75 Volts

 

 

5-540 Amps

 

 

GMAW 50-540 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FCAW 40-540 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STICK 30-540 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pulse

 

 

Pulse

 

Pulse and Background

 

 

 

Pulse

 

 

 

Current Range

Voltage Range

 

 

Time Range

 

 

 

Frequency

 

 

 

 

 

 

 

 

 

 

 

5-750 Amps

5-55 Volts

 

100 Microsec - 3.3 Sec

 

 

0.15 - 1000 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

Type 75°C

 

Type 75°C

 

 

Input

 

Duty

Input Ampere Copper Wire in

Ground Wire in

 

(Super Lag)

 

 

Voltage/

 

Cycle

 

Rating on

 

Conduit

 

Conduit

 

or Breaker

 

 

Freqency

 

 

Nameplate

 

AWG[IEC]

 

AWG[IEC]

 

Size (Amps)

 

 

 

 

 

 

 

 

Sizes (MM2)

 

Sizes (MM2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200/50-60

 

60%

87

4

(25)

 

 

 

8

(10)

 

 

 

 

120

 

230/50-60

 

60%

76

4

(25)

 

 

 

8

(10)

 

 

 

 

100

 

400/50-60

 

60%

44

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

460/50-60

 

60%

38

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

575/50-60

 

60%

32

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

200/50-60

 

100%

75

4 (25)

 

 

 

8

(10)

 

 

 

 

100

 

230/50-60

 

100%

65

4

(25)

 

 

 

8

(10)

 

 

 

 

100

 

400/50-60

 

100%

38

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

460/50-60

 

100%

32

8

(10)

 

 

 

10

(6)

 

 

 

 

50

 

575/50-60

 

100%

28

8

(10)

 

 

 

10

(6)

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

Height

 

 

Width

 

 

Depth

 

 

 

Weight

 

 

 

905 mm

 

 

515 mm

 

 

1010 mm

 

 

 

138 kg

 

 

 

35.6 in.

 

 

20.3 in.

 

 

39.8 in.

 

 

 

304 lbs.

 

 

OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE

0° to 40°C

-50° to 85°C

POWER WAVE 450

Image 11
Contents For use with machines having Code Numbers Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Section C ViiSection D ViiiSeries Section ESection F Section GAwgiec InstallationTechnical Specifications Power Wave Power WaveInput Connections Safety PrecautionsHigh Frequency Precautions Select Suitable LocationGround Connections Input Power ConnectionsInput Fuse and Supply Wire Considerations Input Voltage Reconnect ProcedureWater Cooler Connections Wire Feeder ConnectionsOutput Connections Work and Electrode Cable ConnectionsPower Wave 450 Robotic Dimensions Power Wave 450 Robotic Operating Instructions Safety InstructionsOperation Save process information if desired Select your process informationGeneral Description Case Front Controls Controls and SettingsOverview Installing AN OverlayOperating Overlays Name Overlay TypesOverlay Overlay ID Number = PULSE, GMAW, FCAW, and STICK/TIG Process Selection OverlayOperation Then Select a Memory Location Robotic Interface Weld from MEMORY, Dual Procedure OverlayOperation SET Limit KEY Limit UP / Down Keys Limits Overlay OptionalRecall from Memory KEY Memory Location Numbers Operation Figure B.7 Setup Overlay Setup OverlayTable B.1 Positive Voltage Sensing Options Wire Feeder Setup Description+/- Polarity KEY Positive Polarity Voltage SensingWave Control Overview of Welding ProceduresFlux Cored ARC Welding Fcaw and Gmaw Procedures Pulse ProceduresFcaw Table B.3 Adjustble ParametersGmaw Current Protection Pulse WeldingOverload Protection Thermal ProtectionInterface Description Robot Signal DescriptionsRobotic Interface Water Fault Touch Sense SignalGAS Fault Wire FaultRobot Controller Electrical Characteristics Power Wave CircuitsDual Procedure Switch COM- Mand Wire Stick DetectPower Fault Dual Procedure Switch Command Touch Sense Command ARC DetectGAS Fault Water FaultTouch Sensing Setup Robot Controller SetupWeld System Setup Weld Equipment SetupMiscellaneous Connections Power Wave Interface BoardConnections Arctool Welding Inputs and OutputsPriming the Cooler AccessoriesWater Cooler Usage Recommended CoolantsType L9777 Wire Feed Unit Dimension PrintFor the Latest Connecting Wire Feed Unit to Power Source Mounting the Wire Feed Unit Electrode RoutingDrive Roll and Guide Tube Kits Procedure to Install Drive Roll and Guide TubesSteel Wire Sizes Roll Aluminum Wire SizesIdle Roll Pressure Setting Requires Installation of 2 51MM K162H Spindle KIT Feeding Electrode and Brake AdjustmentFeeding Electrode Wire Loading of 13-14lb 6kg Innershield CoilsTo Mount a 50-60lb 22.7-27.2kg Coil Wire Drive Motor and Gearbox Wire Reel Mounting 50 22.7kg and 60lb 27.2kg CoilsAvoiding Wire Feeding Problems Periodic Maintenance of Wire Drive UnitConnector for 1/16 5/64 1.6 2.0 mm Wire Switch RequirementsInput Filter Capacitor DIS Charge Procedure MaintenanceRoutine and Periodic Maintenance Figure D.1 Resistor Locations Connected Discharge labels, on each of the four SwitchLocate the #9 and #12 terminals, identified by Preventive Maintenance Removing and Installing the G3503 Cooler G3503- Installation or SER Vice Tool UsageG3503- Cooler Service G3503- Cooler Periodic MaintenanceFigure D.4 General Component Locations ED Tests TroubleshootingHOW to USE Troubleshooting Guide Sists, contact your local Lincoln Troubleshooting GuideAuthorized Field Service Facility Play fans run Check circuit breaker 5-amp Observe Safety Guidelines Controls and Settings Power-up Inspect the overlay bar code Saved in memory are different Check for proper shielding gas Basic Course How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Aviso DE