Lincoln Electric IM845-A manual Safety, California Proposition 65 Warnings

Page 2

i

SAFETY

i

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents are known to the State of California to cause can- cer, birth defects, and other reproductive harm.

The Above For Diesel Engines

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

The Above For Gasoline Engines

ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame welding arc or when the engine is running.

Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz- ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods

while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Mar ʻ95

Image 2
Contents Power Wave 355M Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specifications Power Wave 355MSafety Precautions Select Suitable LocationNegative Electrode Polarity Output CABLES, Connections and LimitationsCable INDUCTANCE, and ITS Effects on Pulse Welding Voltage Sensing Work Voltage SensingSystem Description Single Head Feeder Configuring the SystemUP to 4 Wire Feeders Allowed Single Head Boom FeederInstallation Alternate Hard Automatic Application Combination Hard Automation ApplicationTWO Power Waves Welding with Multiple Power WavesControl Cable Specifications Installation Switch Work sense lead Receptacle SpecificationsDIP Switch Settings and Locations Auto mappingRecommended Processes and Equipment OperationGeneral Description Recommended ProcessesDuty Cycle and Time Period Required EquipmentLimitations Case Front ControlsWelding Adjustments Nominal ProceduresFringe Procedures Making a WeldNon Synergic CV Constant Voltage WeldingSynergic CV All CV ModesPulse Welding PULSE-ON-PULSE GMAW-PPSmaw Benefits of Pulse on Pulse from Lincoln ElectricTIG Gtaw ARC GougingPower Mode Recommended Welding Procedures for Power Mode Table B.3Field Installed AccessoriesFactory Installed Optional EquipmentAlways wear a face shield and long sleeves when servicing MaintenanceCapacitor Discharge Procedure For all four capacitorsTroubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Error code before the machine is turned offError Codes for the Powerwave Error Code # IndicationContact your local Lincoln Troubleshooting GuideAuthorized Field Service Facility Problems Possible Areas Recommended Symptoms Contact your local Lincoln Authorized Field Service Facility Troubleshooting Wiring Diagrams Diagrams Connection Diagram Connection Diagram Semi-automatic Simple SystemDimension Print Power Wave 355M Power Wave 355M Precaucion Warnung