Lincoln Electric IM845-A manual Installation, Technical Specifications Power Wave 355M

Page 8

 

A-1

 

 

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 355M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT AC VOLTAGE & DC OUTPUT

 

 

 

Product

Ordering

Input AC

Rated DC Output

Output

Weight

Dimensions

 

 

Name

Information

Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

 

 

 

 

 

 

 

(continuous)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

350A / 34V / 60%

 

 

14.8” x 13.3” x

 

 

POWER

K2368-1

208-230/

 

 

 

27.8”*

 

 

WAVE

 

380-400/

 

AMPS

(81.5 lbs.)

(373 x 338 x

 

 

355M

 

415-460/

 

5-425

(37.0 kg.)

706*)mm

 

 

 

 

 

575

300A / 32V /100%

 

 

 

 

 

 

 

 

50/60 Hz

1& 3 Phase

 

 

* Includes Handles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Overall Length Including Handle, 21.6” (549mm) without handle. Insulation Class 180 (H)

POWER WAVE 355M INPUT CURRENT

Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Phases

300Amps @

350Amps @

Line Cord

Fuse size

Notes

 

 

32Volts(100%)

34Volts(60%)

AWG

 

 

 

 

200

1

Not

Not

 

---

Note 1

 

 

 

 

Recommended

Recommended

 

 

 

 

 

208

1

76

94

2

125A

Note 2

230

1

69

85

4

125A

Note 2

380

1

Not

Not

 

---

Note 1

 

 

Recommended

Recommended

 

 

 

 

 

400

1

Not

Not

---

---

Note 1

 

 

 

Recommended

Recommended

 

 

 

 

 

415

1

41

64

6

80A

Note 2

460

1

36

42

8

70A

 

 

 

575

1

31

37

8

50A

 

 

 

 

 

 

 

 

 

 

200

3

41

50

6

80A

Note 2

208

3

39

50

6

80A

Note 2

230

3

36

42

8

70A

 

 

 

380

3

23

28

8

40A

 

 

 

400

3

22

27

8

40A

 

 

 

415

3

22

26

8

40A

 

 

 

460

3

19

23

8

40A

 

 

 

575

3

16

18

8

30A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. Not rated is indicated by 4-xʼs in the box on the rating plate.

Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Select The output cable size based upon the following chart.*

 

Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:

 

 

 

 

 

 

DUTY CYCLE

CURRENT

LENGTH UP 200FT. (61m)

 

200-250 FT. (61-76m)

100%

300

2/0

 

2/0

60%

350

2/0

 

2/0

 

 

 

 

 

*Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.

POWER WAVE 355M

Image 8
Contents Power Wave 355M Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specifications Power Wave 355MSafety Precautions Select Suitable LocationNegative Electrode Polarity Output CABLES, Connections and LimitationsCable INDUCTANCE, and ITS Effects on Pulse Welding Voltage Sensing Work Voltage SensingSystem Description Configuring the System UP to 4 Wire Feeders AllowedSingle Head Feeder Single Head Boom FeederInstallation Alternate Hard Automatic Application Combination Hard Automation ApplicationTWO Power Waves Welding with Multiple Power WavesControl Cable Specifications Installation Receptacle Specifications DIP Switch Settings and LocationsSwitch Work sense lead Auto mappingOperation General DescriptionRecommended Processes and Equipment Recommended ProcessesRequired Equipment LimitationsDuty Cycle and Time Period Case Front ControlsNominal Procedures Fringe ProceduresWelding Adjustments Making a WeldConstant Voltage Welding Synergic CVNon Synergic CV All CV ModesPulse Welding PULSE-ON-PULSE GMAW-PPBenefits of Pulse on Pulse from Lincoln Electric TIG GtawSmaw ARC GougingPower Mode Recommended Welding Procedures for Power Mode Table B.3Accessories Factory InstalledField Installed Optional EquipmentMaintenance Capacitor Discharge ProcedureAlways wear a face shield and long sleeves when servicing For all four capacitorsTroubleshooting HOW to USE Troubleshooting GuideUsing the Status LED to Error code before the machine is turned offError Codes for the Powerwave Error Code # IndicationContact your local Lincoln Troubleshooting GuideAuthorized Field Service Facility Problems Possible Areas Recommended Symptoms Contact your local Lincoln Authorized Field Service Facility Troubleshooting Wiring Diagrams Diagrams Connection Diagram Connection Diagram Semi-automatic Simple SystemDimension Print Power Wave 355M Power Wave 355M Precaucion Warnung