Lincoln Electric IM845-A manual Problems Possible Areas Recommended Symptoms

Page 31

E-5

TROUBLESHOOTING

E-5

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

Thermal LED is lit.

1. Fan thermostat has opened.

 

 

Check for proper fan operation.

 

 

(Fan should run whenever out-

 

 

put power is on.) Check for

 

 

material blocking intake or

 

 

exhaust louvers, or for excessive

 

 

dirt clogging cooling channels in

 

 

machine. Blow air in rear louvers

 

 

to remove dirt around the fan.

 

 

2. Secondary rectifier or Choke

 

 

thermostat has opened. After

 

 

machine has cooled, reduce

 

 

load, duty cycle, or both. Check

 

 

for material blocking intake or

 

 

exhaust louvers.

 

 

 

 

3. DC Bus PC board thermostat

 

 

has opened check for excessive

 

 

load on 40VDC supply.

 

 

 

 

 

Machine wonʼt weld, canʼt get any

1. Input voltage is too low or too

If all recommended possible areas

output.

high. Make certain that input

 

voltage is proper, according to

of misadjustments have been

 

the Rating Plate located on the

checked and the problem persists,

 

rear of the machine.

 

contact your local Lincoln

 

2. If the Thermal LED is also lit,

Authorized Field Service Facility.

 

see “Yellow Thermal LED is Lit”

 

 

section.

 

 

 

 

3. Primary current limit has been

 

 

exceeded. Possible short in out-

 

 

put circuit. Turn machine off.

 

 

Remove all loads from the out-

 

 

put of the machine. Turn back

 

 

on. If condition persists, turn

 

 

power off, and contact an autho-

 

 

rized

Lincoln

Electric

Field

 

 

Service facility.

 

 

 

 

4. This problem will normally be

 

 

accompanied by an error code.

 

 

Error codes are displayed as a

 

 

series of red and green flashes by

 

 

the

status

light.

See

 

 

"Troubleshooting the Power Wave

 

/Power Feed System Using the Status LED" section of this text.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 355M

Image 31
Contents Power Wave 355M California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Technical Specifications Power Wave 355M InstallationSelect Suitable Location Safety PrecautionsCable INDUCTANCE, and ITS Effects on Pulse Welding Output CABLES, Connections and LimitationsNegative Electrode Polarity Work Voltage Sensing Voltage SensingSystem Description Single Head Boom Feeder Configuring the SystemUP to 4 Wire Feeders Allowed Single Head FeederCombination Hard Automation Application Installation Alternate Hard Automatic ApplicationControl Cable Specifications Welding with Multiple Power WavesTWO Power Waves Installation Auto mapping Receptacle SpecificationsDIP Switch Settings and Locations Switch Work sense leadRecommended Processes OperationGeneral Description Recommended Processes and EquipmentCase Front Controls Required EquipmentLimitations Duty Cycle and Time PeriodMaking a Weld Nominal ProceduresFringe Procedures Welding AdjustmentsAll CV Modes Constant Voltage WeldingSynergic CV Non Synergic CVPULSE-ON-PULSE GMAW-PP Pulse WeldingARC Gouging Benefits of Pulse on Pulse from Lincoln ElectricTIG Gtaw SmawRecommended Welding Procedures for Power Mode Table B.3 Power ModeOptional Equipment AccessoriesFactory Installed Field InstalledFor all four capacitors MaintenanceCapacitor Discharge Procedure Always wear a face shield and long sleeves when servicingHOW to USE Troubleshooting Guide TroubleshootingError code before the machine is turned off Using the Status LED toError Code # Indication Error Codes for the PowerwaveAuthorized Field Service Facility Troubleshooting GuideContact your local Lincoln Problems Possible Areas Recommended Symptoms Contact your local Lincoln Authorized Field Service Facility Troubleshooting Wiring Diagrams Diagrams Connection Diagram Semi-automatic Simple System Connection DiagramDimension Print Power Wave 355M Power Wave 355M Precaucion Warnung