RANGER 305 D settings when using the K930-2 TIG Module with an Amptrol or Arc Start Switch:

Set the MODE Switch to the TOUCH START TIG setting.

Set the "IDLER" Switch to the "AUTO" position.

Set the "WELDING TERMINALS" switch to the "REMOTELY CONTROLLED" position. This will keep the "Solid State" con- tactor open and provide a "cold" electrode until the Amptrol or Arc Start Switch is pressed.

When using the TIG Module, the OUTPUT control on the RANGER 305 D is used to set the maximum range of the CUR- RENT CONTROL on the TIG Module or an Amptrol if connected to the TIG Module.

WIRE WELDING-CV

Connect a wire feeder to the RANGER 305 D according to the instructions in INSTALLATION INSTRUCTIONS Section.

The RANGER 305 D in the CV-WIRE mode, permits it to be used with a broad range of flux cored wire (Innershield and Outershield) electrodes and solid wires for MIG welding (gas metal arc welding). Welding can be finely tuned using the ARC CONTROL. Turning the ARC CONTROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance/pinch control. The proper setting depends on the procedure and operator prefer- ence. Start with the dial set at 0.

Listed below are some wires suitable for use on this machine:

Innershield - NR-311, NS-3M, NR-207, NR-203 Ni 1%, NR-212.

Outershield - 0S-70, 0S-71M, 0S-71 ELITE.

Solid wires for MIG welding - .035 (0.9 mm), and

.045 (1.1 mm), Super Arc L-50 and L-56, .035 (0.9 mm) and

.045 (1.1 mm) Blue Max MIG 308 LS.

Contact your local authorized Lincoln Electric Distributor or the Lincoln Electric Company for specific wires used on certain appli- cations with this machine.

ARC GOUGING

The RANGER 305D can be used for limited arc goug- ing. For optimal performance, set the MODE switch to CC-STICK and the ARC CONTROL to +10.

Set the OUTPUT CONTROL knob to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following Table.

Carbon Diameter

Current Range (DC, electrode

 

positive)

1/8"

60-90 Amps

5/32"

90-150 Amps

3/16"

200-250 Amps

 

 

RANGER 305D

Image 23
Contents Ranger 305D California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents P492 Section DSection E Section FLubrication Emissions Fuel System Governor InstallationHeight Width Depth Weight AIR Cleaner Engine Idler Muffler Engine ProtectionLocation and Ventilation Safety PrecautionsOIL PRE-OPERATION Engine ServiceTowing Vehicle MountingElectrical Connections Total Combined Length of Electrode and Work Cables Cable InstallationWelding Terminals Welding Output CablesStandby Power Connections Auxiliary Power ReceptaclesConnection of Ranger 305D to Premises Wiring Control Cable Model Connection of Lincoln Electric Wire FeedersConnection of LN-15 to the Ranger 305D Across The-Arc ModelConnection of Prince XL Spool GUN to the Ranger 305D Terminals onGeneral Description OperationFigure B.1 Weld Mode Selector SwitchStart Push Button Wire Feeder Voltmeter SwitchGlow Plug Push Button Typical Ranger 305D Fuel Consumption Starting the EngineStopping the Engine Welder OperationTable B.2 TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Downhill Pipe WeldingARC Gouging Wire WELDING-CVRanger 305D Extension Cord Length Recommendations Auxiliary PowerField Installed Options / Accessories AccessoriesKubota D722 Diesel Engine MaintenanceEngine Maintenance Components Kubota D722 Diesel Engine Oil Filter Change AIR CleanerEngine Oil Refill capacities Without oil filter replacement Engine Oil Change3MAINTENANCED-3 Service Instructions & Installation TipsFor Code Cooling SystemTightening the FAN Belt Bleeding the Fuel SystemArrestor Engine AdjustmentBattery Maintenance Servicing Optional SparkGfci Receptacle Testing and RESET- Ting Procedure Welder / Generator MaintenanceHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Authorized Field Service FacilityLincoln Welding without a control cable Functioning properly / linkage Faulty control cable. Repair or Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams Diagrams Engine Welders LN/-8CONNECTION Diagram Diagrams Diagrams Diagrams Diagrams Enhanced For Codes 11188 M20334 Dimension PrintRanger 305D Precaucion Warnung