A-9

INSTALLATION

A-9

 

 

 

7.Set the "IDLE" switch to the "AUTO" position. When not welding, the Ranger 250 engine will be at the low idle speed. If you are using an LN-25 with an internal contactor, the electrode is not energized until the gun trigger is closed.

8.When the gun trigger is closed, the current sens- ing circuit will cause the Ranger 250 engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

Connection of LN-742, K487-25 Spool Gun, and

Cobramatic to Ranger 250

1.Shut the welder off.

2.Connect per instructions on the appropriate con- nection diagram in Section F.

Connection of Prince Spool Gun to the RANGER 250

Connection of the Prince XL Spool Gun requires the use of the K1849-1 Adapter Module.

1.Shut the Welder off.

2.For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

3.Connect the Control Cable of the Spool Gun to the Adapter Module and connect the Control Cable of the Adapter Module to the Welder.

4.Connect the Gas Hose.

5.Set the MODE switch to the "CV-WIRE " position.

6.Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON"

7.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

8.Set the "IDLE" switch to the "HIGH" position.

RANGER 250

Image 17
Contents Ranger California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Section E Section DSection F P490 SeriesInstallation Receptacles and Circuit Breakers Safety Precautions PRE-OPERATION Engine Service Electrical Connections Standby Power Connections Auxiliary Power ReceptaclesCable Installation Total Combined Length of Electrode and Work CablesGND Connection of Ranger 250 to Premises WiringConnection of Lincoln ELEC- Tric Wire Feeders Connection of Prince Spool Gun to the Ranger Operation Design FeaturesGeneral Description Engine OperationARC Control Weld Mode Selector SwitchWelding Controls Engine Controls Welder Operation Typical Current Ranges 1 for Tungsten ELECTRODES2 Wire WELDING-CVTIG Welding Ranger 250 Extension Cord Length Recommendations Auxiliary PowerARC Gouging Recommended Optional Equipment AccessoriesEngine Maintenance Components MaintenanceKohler Engine Onan P220 OHV and ROBIN-SUBARUAIR PRE-CLEANER Service AIR Cleaner ServiceEngine OIL Change Engine OIL Refill CapacitiesAIR Filter Paper Element Spark Plug ServiceSpark Plug Spark Plug GapBattery Maintenance Engine Adjustment Overspeed is HazardousCleaning the Battery Charging the BatteryWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingLincoln Authorized Field Service FacilityPersists,Contact your local Contact your local Lincoln Cause Course of ActionTroubleshooting Troubleshooting Enhanced Diagram DiagramsDiagrams Diagrams Diagrams Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Dimension Print Precaucion Warnung