TROUBLESHOOTING & REPAIR | ||
|
|
MAIN TRANSFORMER REMOVAL AND REPLACEMENT
(MACHINE CODES ABOVE 10150)
(continued)
Return to
Return to Section TOC
Return to
Return to Master TOC
PROCEDURE
1.Remove input power to the
2.Perform Filter Capacitor Discharge Procedure detailed in Maintenance Section.
3.Locate main transformer and associ- ated primary leads. See Figure F.23.
4.Disconnect transformer primary leads #201, #204, #205 and #208 from the power board.
NOTE: Leads #204 and #205 will have to be removed from the T3 cur-
rent transformer. Cut any necessary cable ties. Be sure to note the direction that the leads are thread- ed through the current trans - former. Upon reassembly the leads must be threaded correctly.
5.Locate main transformer and associ- ated secondary leads, reactor leads, and shunt connections. See Figure
F.24.
6.Disconnect and clear the shunt sensing leads from the control board (plug J4).
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
201
204
208
205
T3 CURRENT TRANSFORMER
MAIN TRANSFORMER