TROUBLESHOOTING & REPAIR | ||||
|
| |||
| AUXILIARY TRANSFORMER TEST (continued) |
| ||
| TABLE F.1 Auxiliary Transformer Test Points |
| ||
|
|
|
|
|
| TEST POINT | TEST POINT | EXPECTED VOLTAGE |
|
|
|
|
|
|
| H1 (1J7) | H2 (4J7) | 200 - 208VAC |
|
|
|
|
|
|
| H1 (1J7) | H4 (3J7) | 380 - 415VAC |
|
|
|
|
|
|
| H1 (1J7) | H5 (6J7) | 440 - 460VAC |
|
|
|
|
|
|
| RED LEAD (1J1) | RED LEAD (3J1) | 18VAC (SECONDARY) |
|
| On Control Board | On Control Board |
|
|
|
|
|
|
|
7.If the correct test voltages are pre- sent the auxiliary transformer is good.
8.If any of the voltages are missing or very low, with the proper primary voltage applied, the auxiliary trans- former may be faulty. Replace.
9.If the auxiliary transformer tests good but does not function when connect- ed to the