PROCEDURE
1.Remove input power to the
2.Perform Filter Capacitor Discharge Procedure detailed in Maintenance Section.
3.Locate main transformer and associ- ated primary leads. See Figure F.20.
4.Disconnect transformer primary leads #201, #204, #205 and #208 from the power board.
Note: Leads #204 and #205 will have to be removed from the T3 cur- rent transformer. Cut any necessary
cable ties. Be sure to note the direction that the leads are thread- ed through the current trans -
former. Upon reassembly the leads must be threaded through correctly.
5.Locate main transformer and associ- ated secondary leads, reactor leads, and shunt connections. See Figure F.21.