TROUBLESHOOTING & REPAIR | |||||
| Observe all Safety Guidelines detailed throughout this manual |
| |||
|
|
|
|
|
|
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
| ||
Output turns on momentarily, then 1. | Check the input voltages and | 1. Check Local/Remote switch (S3) | |||
switches off and repeats cycle. | reconnection procedures. Make | and associated wiring for loose or | |||
|
|
| sure the input voltage is correct | faulty connections. |
|
|
|
| for the machine. See Input |
|
|
|
|
| Voltage Reconnect Procedure. 2. Check Mode Switch (S2) and |
| |
|
|
|
| associated wiring for loose or |
|
| 2. | Check or replace remote control | faulty connections. |
| |
|
|
| device. (If used) |
|
|
|
|
|
| 3. If the machine is connected for | |
|
|
|
| 380VAC input or higher, perform | |
|
|
|
| the Capacitor Balance Test. |
|
|
|
|
| 4. The power board may be faulty. | |
|
|
|
| Replace. |
|
|
|
|
| 5. The control board may be faulty. | |
|
|
|
| Replace. |
|
Remote output control not | 1. | Make sure the Local/Remote | 1. | Check the Local/Remote switch |
functioning. The machine operates |
| switch (S3) is in the REMOTE |
| (S3) and the associated wiring. |
normally on LOCAL control. |
| position. |
| See wiring diagram. |
| 2. | The remote control device may | 2. | Check for loose or faulty |
|
| be faulty. Replace. |
| connections at the remote control |
|
|
|
| receptacle. |
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call