B-5

OPERATION

B-5

PARALLEL OPERATION

The Invertec’s are operable in parallel. For best results, the currents of each machine should be rea- sonably well shared. As an example, with two machines set up in parallel for a 300 amp procedure, each machine should be set to deliver approximately 150 amps, not 200 amps from one and 100 amps from the other. This will minimize nuisance feedback conditions. In general, more than two machines in par- allel will not be effective due to the voltage require- ments of procedures in that power range.

To set machine outputs, start with output control pots and arc force pots in identical positions. Adjust out- puts and arc forces to maintain current sharing while establishing the proper output current.

OVERLOAD PROTECTION

The machine is electrically protected from producing high output currents. Should the output current exceed 290A, an electronic protection circuit will reduce the current to less than 200A. The machine will continue to produce this low current until the pro- tection circuit is reset. Reset occurs when the output load is removed.

THERMAL PROTECTION

Thermostats protect the machine from excessive operating temperatures. Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating. If excessive operating temperature should occur, the thermostats will prevent output voltage or current.

Thermostats are self-resetting once the machine cools sufficiently. If the thermostat shutdown was caused by excessive output or duty cycle and the fan is operating normally, the Power Switch may be left on and the reset should occur within a 15 minute period. If the fan is not turning or the air intake louvers were obstructed, then the power must be switched off for 15 minutes in order to reset. The fan problem or air obstruction must also be corrected.

INVERTEC V250-S

Image 17
Contents Invertec V250-S Safety Fumes and Gases can be dangerous Electric Shock can killARC Rays can burn Welding Sparks can cause fire or explosion Cylinder may explode if damagedSûreté Pour Soudage a L’Arc Précautions DE SûretéMaster Table of Contents for ALL Sections Table of Contents Installation Section InstallationThree Phase Technical Specifications Invertec V250-SThree Phase Single Phase Select Suitable Location Safety PrecautionsInput Connections Power Input Connection for 50/60 HZ Machines Input Voltage Reconnect ProcedureInput Fuse and Supply Wire Output Connections Remote Control ReceptacleQuick Disconnect Plugs Output CablesInvertec V250-S Operation Gouging Sparks Safety InstructionsFigure B.1 Case Front Controls Controls and SettingsManual ARC Welding Stick Constant Current ProcessesAIR Carbon ARC Cutting TIG WeldingThermal Protection Parallel OperationOverload Protection Invertec V250-S Table of Contents Accessories Section AccessoriesCable Plugs Options / AccessoriesRemote Controls Table of Contents Maintenance Section MaintenanceFigure D.1 Location of Input Filter Capacitor Terminals Input Filter Capacitor Discharge ProcedureFilter Capacitor Conditioning Routine MaintenanceFigure D.2 Location of Maintenance Components Theory of Operation Table of Contents Theory of Operation SectionInput Line Voltage General DescriptionFigure E.2 Protection and PRE-CHARGE Circuits Precharge and ProtectionFigure E.3 Main Transformer Main TransformerFigure E.4 Output Rectification and Control Output Rectification ControlOverload Protection Protection CircuitsInsulated Gate Bipolar Transistor Igbt Operation Maximum Output Pulse Width ModulationMinimum Output Troubleshooting & Repair Oscilloscope Warning HOW to USE Troubleshooting GuideBoard can be dam- aged by static electricity PC Board Troubleshooting ProceduresCourse of Action Possible Areas Recommended SymptomsPerform the Control Board Voltage Checks Possible AreasCapacitor Balance Test Troubleshooting & Repair Perform the Output Diode Test Welding Problems Invertec V250-S Materials Needed Auxiliary Transformer TestTest Description Auxiliary Transformer Test Test ProcedureTable F.1 Auxiliary Transformer Test Points Auxiliary Transformer TestInvertec V250-S Input Rectifier Test Input Rectifier Test Test ProcedureTest Point Terminals Analog Meter X10 Range Table F.2 Input Rectifier Test PointsInvertec V250-S Power Board Resistance Test Test Description Power Board Resistance TestTable F.3 Power Board Resistance Test Points Power Board Resistance TestInvertec V250-S Output Diodes Test Figure F.4 Machine Output Terminals Output Diodes TestInvertec V250-S Diode Modules Power Board Voltage Test Figure F.8 Plug J6 on Power Board Power Board Voltage TestTest Conditions Table F.4. Power Board Voltage Test PointsAcceptable Test Description Invertec V250-S Control Board Voltage Test Figure F.9 Plugs J1-J5 on Control Board Control Board Voltage Test18VAC Table F.5. Control Board Voltage Test PointsInvertec V250-S Protection Circuit Test Figure F.10 Control Board Plug J2 Test Points Protection Circuit TestProtection Circuit Simplified Invertec V250-S Capacitor Balance Test Capacitor Balance Test Figure F.12 Power Board and Capacitor Test LocationsTable F.6 Capacitor Voltages Invertec V250-S Control Board Removal and Replacement V250S Control Control Board Removal and ReplacementProcedure Power Board Removal and Replacement Figure F.14 Power Board Lead Locations Power Board Removal and ReplacementPower Board Replacement Procedure Invertec V250-S Matched Parts Filter Capacitor Removal and ReplacementFigure F.15 Heatsink/Power Board Removal Filter Capacitor Removal and ReplacementPerform Power Board Replacement Procedure in this section Invertec V250-S Input Rectifier Bridge Removal and Replacement Figure F.16 Input Rectifier Lead Locations Input Rectifier Bridge Removal and ReplacementTroubleshooting & Repair Invertec V250-S Materials Needed Snubber Resistors Locking Tabs Invertec V250-S Wrench Allen type wrench Torque wrench Mounting Bolts Diode Modules Bolted Connections Troubleshooting & Repair Invertec V250-S Main Transformer Removal and Replacement Machine Codes below T3 Current Transformer Main Transformer Main Transformer Secondary Leads Figure F.22 Main Transformer Mountings Clear all leads and secure for case wrap-around assembly Invertec V250-S Main Transformer Removal and Replacement Machine Codes Above Figure F.23 Main Transformer Right Side Figure F.24 Main Transformer Left Side Figure F.25 Main Transformer Mountings Troubleshooting & Repair Invertec V250-S Minimum Acceptable Output AT Maximum Output Settings Maximum Acceptable Output AT Minimum Output SettingsRetest After Repair Input Idle Amps and Idle WattsInvertec V250-S Electrical Diagrams Invertec V250-S Invertec V250S Wiring Diagram Codes 10102Return to Section Wiring Diagram Codes 10187G2666 Control PC Board G2666 LayoutPower P.C. BD. Asbly Power PC Board G2684 LayoutRelay Coils Control PC Board G2666 SchematicFrom Control BD Power PC Board G2684 Schematic