| INSTALLATION |
| |||||||
| TECHNICAL SPECIFICATIONS – |
|
| ||||||||
|
|
|
| INPUT – SINGLE PHASE ONLY |
|
| |||||
| Standard Voltage/Frequency |
|
|
| Input Current |
|
| ||||
|
| 115V/60Hz |
|
| 20 Amps - Rated Output |
|
| ||||
|
| 115V/60Hz |
|
| 25 Amps - Maximum Output | ||||||
|
| 115V/60Hz |
|
| 15 Amps - CSA Rated output | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RATED OUTPUT |
|
|
|
| ||
|
| Duty Cycle |
|
| Amps |
| Volts at Rated Amperes | ||||
| 20% Duty Cycle – Rated DC Output |
| 90 |
|
|
| 18 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTPUT |
|
|
|
| |
| Welding Current Range (Continuous) | Maximum Open Circuit Voltage |
| Auxiliary Power | |||||||
| Rated DC Output: 25 – 135 Amps |
| 28 |
|
|
|
| N/A | |||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
| RECOMMENDED INPUT CABLE AND FUSE SIZES | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Fuse or |
|
|
|
|
|
| |
| Output Mode |
| Input Voltage | Breaker Size | Input Amps |
| Extension Cord |
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Three Conductor |
| ||
|
|
|
|
|
|
|
| #14 AWG |
|
| |
| RATED |
| 115V/60Hz | 20 Amp | 20 |
| (2.1 mm2) or Larger |
| |||
|
|
|
|
|
|
|
| for up to |
|
| |
|
|
|
|
|
|
|
| 25 feet (7.6m) |
|
| |
|
|
|
|
|
|
|
| Three Conductor |
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| #12 AWG |
|
| |
| MAXIMUM |
| 115V/60Hz | 25 Amp | 25 |
| (3.3 mm2) or Larger |
| |||
|
|
|
|
|
|
|
| for up to |
|
| |
|
|
|
|
|
|
|
| 50 feet (15.2 m) |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
PHYSICAL DIMENSIONS
Height | Width | Depth | Weight |
12.0 in | 9.75 in | 16.5 in | 54 Ibs |
305 mm | 248 mm | 419 mm | 24.3 kg |
|
|
|
|