GAS FLOW PROBLEMS

 

 

 

 

 

Low or no gas flow when gun

 

 

1.

Check gas supply, flow regulator

 

 

 

 

 

trigger is pulled. Wire feed, weld

 

 

 

and gas hoses.

 

 

 

 

 

output and fan operate normally.

 

 

 

 

 

 

Contact your local Lincoln

 

 

 

 

 

2.

Check gun connection to

 

 

Authorized Field Service Facility.

 

 

 

 

 

 

machine for obstruction or leaky

 

 

 

 

 

 

 

 

 

seals.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

 

RECOMMENDED

 

 

(SYMPTOMS)

 

 

MISADJUSTMENT(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING PROBLEMS

 

 

 

 

 

Arc is unstable Poor starting

 

 

1. Check for correct input voltage

 

 

 

 

 

 

 

 

 

to machine 115 vac.

 

 

 

 

 

 

 

 

2.

Check for proper electrode

 

 

 

 

 

 

 

 

 

polarity for process.

 

 

 

 

 

 

 

 

3.

Check gun tip for wear or dam-

 

 

Contact your local Lincoln

 

 

 

 

 

 

age Replace.

 

 

Authorized Field Service Facility.

 

 

 

 

 

4.

Check for proper gas and flow

 

 

 

 

 

 

 

 

 

rate for process.

 

 

 

 

 

 

 

 

5.

Check work cable for loose or

 

 

 

 

 

 

 

 

 

faulty connections.

 

 

 

 

 

 

 

 

6.

Check gun for damage or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

breaks.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to Perform the tests/repairs safely, contact your

LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY for assistance before you proceed.

SP-135 PLUS

Image 42
Contents Safety Depends on You SP-135 PlusSafety Electric Shock can kill Safety IiiSP-135 Plus Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Installation Technical Specifications SP-135 PlusSafety Precautions Identify and Locate ComponentsElectric Shock can kill Select Suitable Location Work Clamp InstallationWork Cable Installation StackingGAS Connection GUN InstallationConnecting Gun Cable to the SP-135 PlusInput Input ConnectionsGas Solenoid Inlet Fitting CableCode Requirements for Input Connections Requirements For Rated OutputRequirements For Maximum Output Fumes and Gases can be dangerous Observe all safety information throughout this manualOperation Welding Sparks can cause fire or explosionGeneral Description Controls and SettingsDesign Features Advantages Welding CapabilityWire Loading Welding OperationsSequence of Operation 4OPERATIONB-4 Shielding Gas Making a WeldChanging Machine Over to Feed Other Wire Sizes Cleaning Tip And NozzleProcess Guidelines Output Overload Wire Feed Overload ProtectionOverload Protection Thermal ProtectionARC-WELDING Circuit Learning to WeldLearning to Weld SELF-SHIELDED Fcaw Welding ARCGmaw MIG Welding ARC Process SelectionFor Gmaw MIG Process Common MetalsJoint Types and Positions For Fcaw Innershield ProcessWelding In The Vertical Position PenetrationFillet Welds Vertical-down Welding Machine SET UP for the SELF-SHIELDED Fcaw ProcessWelding Techniques for the Self Shielded Fcaw Process Correct Welding PositionCorrect Electrical Stickout ESO Correct Welding SpeedHelpful Hints PracticeMachine SET UP for the Gmaw MIG Process Welding Techniques for the Gmaw MIG ProcessFigure B.24 To Correct Poor Penetration in order of impor- tance Troubleshooting WeldsTo Eliminate a Ropy Convex Bead in order of importance To Eliminate Stubbing* in order of importanceProper Gun Handling Application Chart Accessories Optional AccessoriesK586-1 Deluxe Adjustable Gas Regulator Hose Kit Replacement Parts Innershield Fcaw ConversionItems Requiring no Maintenance MaintenanceMaintenance Safety Precautions Routine and Periodic MAINTE- NanceFor Magnum 100L GUN GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System Contact Tip Cable Liner Drive RollChanging the Contact TIP Changing Drive RollChanging Liner GUN Handle PartsLiner trim length for gun with red trigger Magnum 100L Troubleshooting HOW to USE Troubleshooting GuideTroubleshooting Guide Problems Possible Areas Symptoms MisadjustmentsRecommended Course of Action Feeding Problems GAS Flow Problems Wiring DiagramsSP-135 Plus Need Welding Training? How To Read Shop DrawingsNew Lessons in Arc Welding $700.00Precaucion Warnung