Lincoln Electric IM725 Code Requirements for Input Connections, Requirements For Rated Output

Page 13

A-6

INSTALLATION

A-6

CODE REQUIREMENTS FOR INPUT CONNECTIONS

WARNING

This welding machine must be connected to power source in accordance with applicable elec- trical codes.

The United States National Electrical Code (Article 630-B, 1990 Edition) provides standards for amperage handling capability of supply conductors based on duty cycle of the welding source.

If there is any question about the installation meeting applicable electrical code requirements, consult a qualified electrician.

Requirements For Rated Output

A power cord with a 15 amp, 125 volt, three prong plug (NEMA Type 5-15P) is factory installed on the SP-135 PLUS. Connect this plug to a mating ground- ed receptacle which is connected to a 20 amp branch circuit with a nominal voltage rating of 115 to 125 volts, 60 Hertz, AC only.

The rated output with this installation is 90 amps, 18 Volts, 20% duty cycle (2 minutes of every 10 minutes used for welding).

CAUTION

Do not connect the SP-135 PLUS to an input power supply with a rated voltage that is greater than 125 volts.

Do not remove the power cord ground prong.

Requirements For Maximum Output

In order to utilize the maximum output capability of the machine, a branch circuit capable of 25 amps at 115 to 125 volts, 60 Hertz is required. This generally applies when welding steel that is equal to or greater than 12 gauge, 0.105(2.5 mm) in thickness.

SP-135 PLUS

Image 13
Contents SP-135 Plus Safety Depends on YouSafety Electric Shock can kill Iii SafetySP-135 Plus Sûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Technical Specifications SP-135 Plus InstallationIdentify and Locate Components Safety PrecautionsElectric Shock can kill Work Cable Installation Work Clamp Installation Select Suitable Location StackingConnecting Gun Cable to the SP-135 GUN InstallationGAS Connection PlusGas Solenoid Inlet Fitting Input ConnectionsInput CableRequirements For Rated Output Code Requirements for Input ConnectionsRequirements For Maximum Output Operation Observe all safety information throughout this manualFumes and Gases can be dangerous Welding Sparks can cause fire or explosionDesign Features Advantages Controls and SettingsGeneral Description Welding CapabilityWelding Operations Wire LoadingSequence of Operation 4OPERATIONB-4 Making a Weld Shielding GasCleaning Tip And Nozzle Changing Machine Over to Feed Other Wire SizesProcess Guidelines Overload Protection Wire Feed Overload ProtectionOutput Overload Thermal ProtectionLearning to Weld Learning to WeldARC-WELDING Circuit SELF-SHIELDED Fcaw Welding ARCProcess Selection Gmaw MIG Welding ARCJoint Types and Positions Common MetalsFor Gmaw MIG Process For Fcaw Innershield ProcessPenetration Welding In The Vertical PositionFillet Welds Welding Techniques for the Self Shielded Fcaw Process Machine SET UP for the SELF-SHIELDED Fcaw ProcessVertical-down Welding Correct Welding PositionCorrect Welding Speed Correct Electrical Stickout ESOPractice Helpful HintsWelding Techniques for the Gmaw MIG Process Machine SET UP for the Gmaw MIG ProcessFigure B.24 To Eliminate a Ropy Convex Bead in order of importance Troubleshooting WeldsTo Correct Poor Penetration in order of impor- tance To Eliminate Stubbing* in order of importanceProper Gun Handling Application Chart Optional Accessories AccessoriesK586-1 Deluxe Adjustable Gas Regulator Hose Kit Innershield Fcaw Conversion Replacement PartsMaintenance Safety Precautions MaintenanceItems Requiring no Maintenance Routine and Periodic MAINTE- NanceConfiguration of Components in Wire Feeding System GUN and Cable MaintenanceFor Magnum 100L GUN Contact Tip Cable Liner Drive RollChanging Drive Roll Changing the Contact TIPGUN Handle Parts Changing LinerLiner trim length for gun with red trigger Magnum 100L HOW to USE Troubleshooting Guide TroubleshootingProblems Possible Areas Symptoms Misadjustments Troubleshooting GuideRecommended Course of Action Feeding Problems GAS Flow Problems Diagrams WiringSP-135 Plus New Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? $700.00Precaucion Warnung