Lincoln Electric 575 manual Installation

Page 11

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - Vantage 575 (K2170-1)

INPUT - DIESEL ENGINE

Make /Model

Description

Speed (RPM)

Displacement

Starting

Capacities

 

 

 

 

System

 

Cummins

4 cylinder

High Idle 1590

3.3L

12VDC battery

Fuel 94.6L

B3.3

36kw (48 HP)

Low Idle 1300

(199 cu in)

& Starter

(25 US gal)

Diesel Engine

@ 1500 RPM

Full Load 1500

 

 

 

 

 

 

Bore x Stroke

 

Oil: 7.5L

 

 

 

 

 

(2 US gal)

 

 

 

95mm x 115mm

 

 

 

 

 

(3.74” x 4.53”)

 

Coolant: 11.8L

 

 

 

 

 

(2.6 US gal)

 

 

 

 

 

 

RATED OUTPUT @ 40°C(104°F) - WELDER

Duty Cycle

Welding Output

Volts at Rated Amps

100%

450 Amps (DC multi-purpose)

38 Volts

60%

500 Amps (DC multi-purpose)

40 volts

 

 

 

OUTPUT @ 40°C(104°F) - WELDER AND GENERATOR

Welding Range

30 - 500 Amps CC/CV

20 - 250 Amps TIG

Open Circuit Voltage

60 Max OCV @ 1590 RPM

 

Auxiliary Power (1)

(50 HZ)

 

Outlets x Phase

Voltage

Power

Amps

1 x 3ph

380 Volt

12kVA

18.5 Amps

3 x 1ph

220 Volt

10kVA

15 Amps

PHYSICAL DIMENSIONS

Height (2)

Width

Depth

Weight

1067mm

800mm

1603mm

737kg

(42.0 in)

(31.5in)

(63.1in)

(1625lbs)

 

 

 

(Approx)

(CTE) Centre Tapped Earth

1.Output rating in watts is equivalent to volt-amperes at unity power factor.

Output voltage is within +/- 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

2.Top of Enclosure. Add 223.5mm (8.8”) for exhaust.

Vantage 575

Image 11
Contents Vantage Safety Electric Shock can kill For Electrically powered equipment Précautions DE Sûreté SafetyWELDING, EMF & Pacemakers Instructions for Electromagnetic Compatibility Thank You Table of Contents Accessories Section C Installation Location / Ventilation InstallationSafety Precautions Towing High Temperature OperationLifting High Altitude OperationPRE-OPERATION Engine Service Welding Terminals Output Remote ControlAuxiliary Power Receptacles Standby Power ConnectionsConnection of Lincoln Electric Wire Feeders Connection of Prince XL Spool GUN to the Vantage Connection of the LN-25 to the VantageRecommended Applications Safety InstructionsOperation General DescriptionHour Meter RUN Stop SwitchEngine Temperature Gauge Start PushbuttonEngine Protection Battery Charging LightIdler Switch OIL Pressure GaugeAuxiliary Power Controls Stopping the Engine Engine OperationStarting the Engine BREAK-IN Period For Tungsten Electrodes OperationAuxiliary Power Operation Table B.4 Vantage Simultaneous Welding and Power Loads Optional Field Installed Accessories AccessoriesEngine Maintenance MaintenanceRoutine and Periodic Maintenance Cooling System Battery HandlingFuel Filters Welder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Misadjustments Course of Action Problems Possible Areas RecommendedVantage 575 Wiring Diagram K2170-1 50HZ DiagramsDIAGRAMSF-2 Commander / K867 / K775 / LN-7 Connection Diagram Diagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Dimension Print Vantage Vantage Aviso DE Precaucion