TROUBLESHOOTING | ||
|
|
|
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
FUNCTION PROBLEMS
Engine goes to low idle but does not stay at | 1. | Faulty Peripheral PCB, Pull Coil/Battery |
low idle. |
| PCB or Weld Control PCB. |
|
|
|
No welding output or auxiliary output. | 1. | Broken lead in rotor circuit. |
| 2. | Faulty field diode module. |
| 3. | Faulty Weld Control P.C. Board. |
| 4. | Faulty rotor. |
|
| |
Welder has some/ no output and no control. | 1. Faulty remote kit. | |
Auxiliary output OK | 2. | Faulty output control potentiometer. |
| 3. | Faulty output control wiring. |
| 4. | Faulty Weld Control PCB, Pull |
|
| Coil/Battery PCB or Chopper PCB. |
|
|
|
No welding output. Auxiliary output OK. | 1. | WELDING TERMINALS switch in wrong |
|
| position, be sure switch is in WELDING |
|
| TERMINALS ALWAYS ON position. |
| 2. | Faulty Weld Control PCB, Pull |
|
| Coil/Battery PCB or Chopper PCB. |
|
| |
No auxiliary power. | 1. Open circuit breakers. | |
| 2. | Faulty connections to auxiliary |
|
| receptacles. |
| 3. Faulty auxiliary circuit wiring. | |
|
|
|
|
|
|
If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
______________________________________________________________________________________________________________
Vantage 575