OPERATION |
|
| ||||
|
| TABLE B.4 Vantage |
|
|
| |
|
| Simultaneous Welding and Power Loads |
|
| ||
|
|
|
|
|
|
|
|
| Permissible |
| Permissible Auxiliary |
| |
| Welding Output | Power - Watts |
| Current in Amperes |
| |
|
|
| ||||
|
| (Unity Power |
|
|
|
|
|
|
|
|
|
| |
|
| Factor | @220 V ±10% * | @ 380 V ±10% |
| |
|
|
|
|
|
|
|
| 0 | 0 |
| 0 |
| |
| 350A/34V | 8100 | 40* |
| 14 amp/phase |
|
| 200A/30V | 12000 | 50* |
| 18.5 amp/phase |
|
| 150A/26V | 12000 | 50* |
| 18.5 amp/phase |
|
| 90A/24V | 12000 | 50* |
| 18.5 amp/phase |
|
|
|
|
|
|
|
|
*Each receptacle is limited to 15 amps.
TABLE B.5 Vantage
Extension Cord Length Recommendations
Current | Voltage | Load |
|
|
| Maximum Allowable Cord Length in m (ft) for Conductor Size |
|
| ||||||
(Amps) | Volts) | (Watts) | 2.52mm (14AWG) | 4.02mm | (12AWG) | 6.02mm | (10AWG) | 10.02mm | (8AWG) | 16.02mm | (6AWG) | 25.02mm | (4AWG) | |
15 | 230 | 3600 | 18 | (60) | 23 | (75) | 46 | (150) | 69 | (225) | 107 | (350) | 183 | (600) |
20 | 230 | 4800 |
|
| 18 | (60) | 30 | (100) | 53 | (175) | 84 | (275) | 1373 | (450) |
Conductor size is based on maximum 2.0% voltage drop
Vantage 575