Lincoln Electric 575 manual Table B.4 Vantage Simultaneous Welding and Power Loads

Page 27

B-9

OPERATION

 

 

B-9

 

 

TABLE B.4 Vantage

 

 

 

 

 

Simultaneous Welding and Power Loads

 

 

 

 

 

 

 

 

 

 

 

Permissible

 

Permissible Auxiliary

 

 

Welding Output

Power - Watts

 

Current in Amperes

 

 

 

 

 

 

(Unity Power

 

 

 

 

 

 

 

 

 

 

 

 

Factor

@220 V ±10% *

@ 380 V ±10%

 

 

 

 

 

 

 

 

 

500A-40V

0

0

 

0

 

 

350A/34V

8100

40*

 

14 amp/phase

 

 

200A/30V

12000

50*

 

18.5 amp/phase

 

 

150A/26V

12000

50*

 

18.5 amp/phase

 

 

90A/24V

12000

50*

 

18.5 amp/phase

 

 

 

 

 

 

 

 

*Each receptacle is limited to 15 amps.

TABLE B.5 Vantage

Extension Cord Length Recommendations

Current

Voltage

Load

 

 

 

Maximum Allowable Cord Length in m (ft) for Conductor Size

 

 

(Amps)

Volts)

(Watts)

2.52mm (14AWG)

4.02mm

(12AWG)

6.02mm

(10AWG)

10.02mm

(8AWG)

16.02mm

(6AWG)

25.02mm

(4AWG)

15

230

3600

18

(60)

23

(75)

46

(150)

69

(225)

107

(350)

183

(600)

20

230

4800

 

 

18

(60)

30

(100)

53

(175)

84

(275)

1373

(450)

Conductor size is based on maximum 2.0% voltage drop

Vantage 575

Image 27
Contents Vantage Safety Electric Shock can kill For Electrically powered equipment Précautions DE Sûreté SafetyWELDING, EMF & Pacemakers Instructions for Electromagnetic Compatibility Thank You Table of Contents Accessories Section C Installation Installation Safety PrecautionsLocation / Ventilation Towing High Temperature OperationLifting High Altitude OperationPRE-OPERATION Engine Service Welding Terminals Output Remote ControlAuxiliary Power Receptacles Standby Power ConnectionsConnection of Lincoln Electric Wire Feeders Connection of Prince XL Spool GUN to the Vantage Connection of the LN-25 to the VantageRecommended Applications Safety InstructionsOperation General DescriptionHour Meter RUN Stop SwitchEngine Temperature Gauge Start PushbuttonEngine Protection Battery Charging LightIdler Switch OIL Pressure GaugeAuxiliary Power Controls Engine Operation Starting the EngineStopping the Engine BREAK-IN Period For Tungsten Electrodes OperationAuxiliary Power Operation Table B.4 Vantage Simultaneous Welding and Power Loads Optional Field Installed Accessories AccessoriesMaintenance Routine and Periodic MaintenanceEngine Maintenance Battery Handling Fuel FiltersCooling System Welder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Misadjustments Course of Action Problems Possible Areas RecommendedVantage 575 Wiring Diagram K2170-1 50HZ DiagramsDIAGRAMSF-2 Commander / K867 / K775 / LN-7 Connection Diagram Diagrams Diagrams Commander / K867 / LN-8 Connection Diagram Diagrams Diagrams Engine Welders /LN-8 Connection Diagram Diagrams Diagrams Diagrams Diagrams Dimension Print Vantage Vantage Aviso DE Precaucion