Lincoln Electric 5000 manual Warnung

Page 49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keep your head out of fumes.

Turn power off before servicing.

Do not operate with panel open or

 

WARNING

 

 

remove fumes from breathing zone.

 

 

 

 

guards off.

 

 

Use ventilation or exhaust to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Los humos fuera de la zona de res-

Desconectar el cable de ali-

No operar con panel abierto o

Spanish

 

 

piración.

 

mentación de poder de la máquina

 

guardas quitadas.

 

AVISO DE

 

Mantenga la cabeza fuera de los

 

antes de iniciar cualquier servicio.

 

 

 

 

 

 

aspiración para gases.

 

 

 

 

 

 

PRECAUCION

 

 

humos. Utilice ventilación o

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gardez la tête à l’écart des fumées.

Débranchez le courant avant l’entre-

N’opérez pas avec les panneaux

French

 

Utilisez un ventilateur ou un aspira-

 

tien.

 

ouverts ou avec les dispositifs de

ATTENTION

 

 

teur pour ôter les fumées des zones

 

 

 

 

protection enlevés.

 

 

de travail.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vermeiden Sie das Einatmen von

Strom vor Wartungsarbeiten

Anlage nie ohne Schutzgehäuse

German

 

 

Schweibrauch!

 

abschalten! (Netzstrom völlig öff-

 

oder Innenschutzverkleidung in

WARNUNG

 

Sorgen Sie für gute Be- und

 

nen; Maschine anhalten!)

 

Betrieb setzen!

 

 

Entlüftung des Arbeitsplatzes!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mantenha seu rosto da fumaça.

Não opere com as tampas removidas.

Mantenha-se afastado das partes

Portuguese

 

 

ATENÇÃO

 

Use ventilação e exhaustão para

Desligue a corrente antes de fazer

 

moventes.

 

 

 

remover fumo da zona respiratória.

 

serviço.

Não opere com os paineis abertos

 

 

 

 

 

 

 

 

Não toque as partes elétricas nuas.

 

ou guardas removidas.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Japanese

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chinese

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Korean

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Arabic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.

Image 49
Contents Safety Depends on You Power ARCCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Technical Specifications Power ARC InstallationLocation and Ventilation Safety PrecautionsStoring Tilting StackingLifting Assembly of Wheels and Handle to the Tube Frame OIL PRE-OPERATION Engine ServiceFuel Spark ArresterWelding Cable Connections Electrical Output ConnectionsCable Installation Auxiliary Power ReceptaclesMachine Grounding Premises Wiring Power Cord Connections to TWIST- Lock PlugsPlugs and HAND-HELD Equipment Circuit BreakersThese Devices Without Operation Safety InstructionsOperating Instructions General DescriptionWelding Capability Recommended ApplicationsLimitations GENERATOR/WELDER Controls Controls and SettingsGasoline Engine Controls Figure B.2 Gasoline Engine ControlsBefore Starting the Engine Engine OperationStarting the Engine BREAK-IN Period Stopping the EngineFor a HOT Engine For Best Engine StartingGenerator Operation To USE the Generator AS AN Auxiliary Power SupplyGeneral Information Suggested Power Applications Running Watts Start-up Watts Table B.3 Generator Power ApplicationsWelding Operation To USE the Power ARC 5000 for Stick WeldingControl Function / Operation Current Control Dial After YOU Finish the WeldWelding Guidelines Stick Welding Figure B.4 The welding arc What Happens in the Arc?Correct Way to Strike An Arc Correct Welding Position Correct Arc LengthCorrect Welding Speed Common Metals PracticeTypes of Welds Fillet Welds PenetrationMultiple Pass Welds Welding in the Vertical PositionVertical-Down Welding Vertical-Up WeldingOverhead Welding How to Hardface the Sharp Edge Metal to Ground WearWelding Sheet Metal Hardfacing To Reduce WearCast Iron Plate Preparation Welding Cast IronOut-of-Position Group AWS E6011 Selecting ElectrodesHigh-Speed Group AWS E6013 Low Hydrogen Group Stable-Arc E7018OPTIONS/ACCESSORIES AccessoriesLincoln Electric Accessories Briggs and Stratton AccessoriesRoutine and Periodic Maintenance MaintenanceEngine Maintenance Engine AdjustmentsClean AIR Filter PRE-CLEANER Figure D.3 Clean Cooling SystemPart Part Number Table D.2 Engine Maintenance PartsFigure D.6. Brush Removal and Replacement GENERATOR/WELDER MaintenanceFigure D.7. Major Component Locations Symptoms TroubleshootingPossible Areas Generator POWER, Always Not RUN Engine Without AN Wiring Diagram Power ARC DiagramsDimension Print New Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? Basic CoursePrecaucion Warnung