Craftsman 919.724582 Assembly, Installation, Unpacking, Location of the Air Compressor

Page 10

ASSEMBLY

Unpacking

1.Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration

as the grounded plug. DO NOT USE AN ADAPTER. See

illustration.

Plug

Grounded

Outlets

Grounding Pin

GROUNDING INSTRUCTIONS

Risk of Electrical Shock. In the

event of a short circuit, grounding reduces the risk of shock by providing an escape wire for

the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical

Shock. Improper grounding can result in electrical shock.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

A07187

10- ENG

Image 10
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Preventing Equipment PROBLEMS. To help you recognize thisHazard Always remain in attendance withTank is designed to withstand specific Accessories, tires, and other inflatablesSoft tissue damage to exposed skin For essential control of air pressure, youTo human consumption Electricity. Like any other electricallyRepairs attempted by unqualified Your specific application Result in serious burns How To Prevent It What Could HappenKeep children away from the air compressor at all times Transporting CompressorEquip area of operation with a fire extinguisher Glossary AccessoriesAccessories Duty CycleUnpacking AssemblyInstallation Location of the Air CompressorExtension Cords Voltage and Circuit ProtectionKnow Your Air Compressor Tank Pressure Gauge Auto/Off Switch OutletOperation Description of OperationCheck Valve Drain How to StopBefore Starting Pressure Release ValveHow to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankAir Compressor Pump Intake and Exhaust Valves Air Filter Inspection and ReplacementMotor Pressure Relief Tube Nut Outlet Service and AdjustmentsTo Replace or Clean Check Valve Screwdriver Open position nothing is visibleStorage Troubleshooting Pressure reading Problem Cause Correction Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Mesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Conserver ces directives Avertissement Risque dexplosion ou dincendie PréventionRisque Prévention Avertissement Risque déclatementAvertissement Risque de projection dobjets Avertissement Risque de choc électrique Avertissement Risque par inhalation PréventionAvertissement Risque relié aux pièces mobiles Avertissement Risque de brûluresAvertissement Risque de chute Risque Avertissement Risque dune utilisation dangereuseAccessoires AccessoiresCycle DE Service LexiqueAssemblage DéballageRallonges Protection contre la surtension et protection du circuitFamiliarisez-vous avec votre compresseur dair UtilisationDescription du fonctionnement Arrêt de lappareil Avant le démarrageAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirRisque de brûlures Filtre à air Inspection et remplacementMoteur Risque dune utilisationEntretien ET Réglages Tous les services dentretienRemplacement ou nettoyage de la soupape de retenue Ne figurant pas ici doivent êtreRangement Risque déclatement.Ne DépannageSerrer Peut éclater ou exploserProblème Cause Correctif Le moteur ne 50- FR 51- FR A07187 Sears Parts and Repair Center MY-HOMECanada