Friedrich service manual Chassis Specifications for 2009, 2008 models

Page 9

Chassis Specifications for 2009, 2008 models

ENERGY STAR® Models

 

Cooling

Heating

Electrical Characteristics (60 Hertz)

 

 

 

 

 

 

 

Capacity

Capacity

Volts

Cooling

Cooling

Heating

Heating

Model

BTU/h

Rated

Rated

Amps

Watts

Amps

Watts

Energy Coefficient

Efficiency Of

Ratio Performance

EER COP

Moisture

Room Side

Weight

Removal

Air Circulation

Lbs.

Pints/Hr.

CFM

Sleeve* Ship/Net

ULTRA PREMIUM LINE

QUIETMASTER Programmable

SS08L10

 

8400

115

6.6

737

11.4

 

1.6

265

S

114/108

SS10L10

 

10400

115

7.5

867

12.0

 

2.5

260

S

121/115

SS12L10

 

11800

115

9.0

1000

11.8

 

2.5

350

S

120/114

SS14L10

 

14000

115

12.0

1305

10.7

 

3.5

377

S

134/128

SS12L30

 

12100/11900

230/208

4.8/5.0

1052/1017

11.5/11.7

 

2.9

320

S

120/114

SS16L30

 

16200/15900

230/208

7.4/8.0

1653/1656

9.8/9.6

 

4.7

360

S

125/119

SM18L30A

 

17500/17300

230/208

7.2/7.7

1620/1570

10.8/10.8

 

4.5

375

M

169/163

SM21L30

 

20600/20200

230/208

9.4/10.1

2081/2020

9.9/10.0

 

6.0

425

M

160/154

SM24L30

 

23500/23000

230/208

11.2/12.1

2479/2421

9.5/9.5

 

7.0

400

M

160/154

XSTAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XQ05L10A

 

5500

115

5.0

500

11.0

 

1.2

200

Q

76/70

XQ06L10A

 

6300

115

4.9

548

11.5

 

1.4

175

Q

76/70

XQ08L10A

 

8000

115

6.8

741

10.8

 

1.9

175

Q

83/77

XQ10L10A

 

10000

115

9.0

1000

10.0

 

3.2

180

Q

89/83

XQ12L10A

 

11700

115

11.0

1198

9.8

 

3.2

200

Q

89/83

PREMIUM LINE

 

 

 

 

 

 

 

 

 

 

 

 

QUIETMASTER

 

 

 

 

 

 

 

 

 

 

 

 

 

KS12L10

 

11600

115

9.0

1055

11.0

 

2.5

356

S

120/114

KS15L10

 

14500

115

12.0

1343

10.8

 

3.5

377

S

134/128

KM18L30

 

17800/17600

230/208

8.1/8.8

1780/1760

10.0/10.0

 

4.4

400

M

167/161

KM24L30

 

23500/23000

230/208

11.2/12.1

2479/2421

9.5/9.5

 

7.0

400

M

160/154

SL28L30

 

28000/27700

230/208

13.0/14.2

2947/2916

9.5/9.5

 

8.8

600

L

207/201

SL36L30A

 

36000/35700

230/208

18.0/19.6

4235/4200

8.5/8.5

 

11.0

725

L

226/220

TWINTEMP Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

YS09L10**

 

9200

7400

115

7.4

767

6.9

733

12.0

3.0

1.7

300

S

117/113

YS13L33

 

12700/12500

11000/10500

230/208

5.1/5.6

1149/1131

5.3/5.8

1185/1167

11.0/11.0

2.5/2.6

3.5

325

S

121/117

YM18L34

 

18000/18000

16800/16400

230/208

8.5/9.5

1895/1895

8.5/9.0

1867/1822

9.5/9.5

2.8/2.9

4.7

400

M

170/166

YL24L35

 

24000/24000

22000/21600

230/208

10.9/12.0

2400/2400

11.0/12.0

2444/2400

10.0/10.0

2.7/2.8

7.0

600

L

202/198

TWINTEMP Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

EQ08L11A

 

7700

4000

115

6.5

733

11.2

1290

10.5

 

1.9

175

Q

80/76

ES12L33

 

12100/11900

10700/8900

230/208

4.8/5.0

1052/1017

16.0/14.7

3500/2900

11.5/11.7

 

2.9

320

S

115/111

ES16L33

 

16200/15900

10700/8900

230/208

7.4/8.0

1653/1656

16.0/14.7

3500/2900

9.8/9.6

 

4.7

360

S

120/116

EM18L34

 

17800/17600

13000/10600

230/208

8.1/8.8

1780/1760

19.5/17.0

4200/3500

10.0/10.0

 

4.4

400

M

164/160

EM24L34

 

23500/23000

13000/10600

230/208

11.2/12.1

2479/2421

19.5/17.0

4200/3500

9.5/9.5

 

7.0

400

M

160/154

EL36L35A

 

36000/35700

17300/14300

230/208

18.0/19.6

4235/4200

24.0/22.4

5500/4650

8.5/8.5

 

11.0

725

L

224/220

*Sleeve dimensions listed on opposite page.

**Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 50° F to 115° F.

TwinTemp Heat Pump heating information (shown in red) indicates heat pump heating performance. TwinTemp Electric Heat heating information (shown in red) indicates electric heat strip performance. For TwinTemp Heat Pump electric heating performance refer to corresponding TwinTemp Electric Heat model.

Due to continuing research in new energy-saving technology, specifications are subject to change without notice.

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® () models meet the ENERGY STAR® guidelines for energy efficiency.

The consumer- through the AHAM Room Air Conditioner Certification Program- can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.

7

Image 9
Contents Room Air Conditioners Technical Support Contact Information Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards Typical Unit Components Introduction2nd Digit 1st Digit Function7th Digit Options 0 = Straight Cool & Heat Pump Models 6th Digit Voltage 1 = 115 VoltsChassis Specifications for 2009, 2008 models Installation information / sleeve dimensions Performance Data for 2009, 2008 models Fire Hazard Electric Shock HazardMake sure the wiring is adequate for your unit To start unit To adjust temperature 60F 16C to 90F 32CHow to use the remote control* QuietMaster Programmable How to operate the Friedrich room air conditioner XQ models How to use the remote control XQ models How to operate the Friedrich room air conditioner Testing the Electronic Control Boards for QME & XQ Models Checking Room TemperatureActivating Test Mode Testing the Electronic Control Error Code Listings KS, KM, SL Models See Figure Testing the Rotary Control SwitchesFunctional Component Definitions EQ08 System Control Switch TestMechanical Components Electrical ComponentsThermostat Adjustment Components TestingTest Thermostat Bulb LocationResistor Heat Anticipator See Figure Defrost Thermostat Heat Pump Models OnlyDefrost Bulb Location Heat Pump Models Capacitor Check with Capacitor Analyzer CapacitorsCapacitor Connections FAN MotorHeating Element See Figure Testing the Heating Element Electric Shock HazardHeating Element Heat Pump Models Drain PAN ValveSmart FAN Operating Sequence / Characteristics and FeaturesRefrigeration Sequence of Operation Equipment Required Sealed Refrigeration System RepairsEquipment Must be Capable Risk of Electric ShockMethod Of Charging / Repairs Burn HazardFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Metering Device Hermetic Components CheckCheck Valve Capillary Tube SystemsReversing Valve DESCRIPTION/OPERATION Checking the Reversing Valve Testing the CoilProcedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleExplosion Hazard Compressor Checks Single Phase Resistance Test Ground TestChecking Compressor Efficiency Compressor Replacement Recommended procedure for compressor replacementHigh Temperatures Rotary Compressor Special Troubleshooting and Service Coils and Base PAN Excessive Weight Hazard Routine MaintenanceBlower Wheel / Housing / Condenser FAN / Shroud AIR FilterFront Cover Sleeve / DrainProblem Possible Cause Action Cooling only Room AIR Conditioners Troubleshooting TipsReplace fuse, reset breaker. If repeats, check Fused separately Problem Possible Cause Action Heat / Cool only Room AIR Conditioners Troubleshooting Tips Problem Possible Cause Action Heat / Cool Room AIR Conditioners Trouble Shooting TipsSystem Cools When Heating is Desired Heat PumpYES Malfunction of Valve Normal Function of ValveElectronic Control Cool only Models Electronic Control Cool only Models Electromechanical Control Cool only Models SL28L30-D,-E SL36L30A-D,A-E Page Electromechanical Control Cool with Electric Heat Models EL36L35A-D,A-E Electromechanical Control Heat Pump only Models YS13L33-D,-E YM18L34-D,-E YL24L35-E,-F Aham PUB. NO. RAC-1 Cooling Load Estimate Form Heat Gain from Quantity FactorsDAY Heat Load Form Following is an example using the heat load formInfiltration Windows & Doors AVG Windows & Doors Area, sq. ftRoom AIR Conditioners Limited Warranty Page Technical Support Contact Information Friedrich AIR Conditioning CO
Related manuals
Manual 60 pages 54.38 Kb Manual 60 pages 45.7 Kb

2009, 2008 specifications

Friedrich 2008 and 2009 represent significant advancements in heating and cooling technology, particularly in the realm of air conditioning systems. Friedrich is known for producing robust and efficient HVAC solutions tailored for both residential and commercial applications. These models are particularly noteworthy for their innovative features and energy-efficient technologies that enhance user comfort and lower operational costs.

One of the main characteristics of the Friedrich 2008 and 2009 models is their emphasis on energy efficiency. Both units are designed to meet or exceed Energy Star standards, which indicates that they use less energy compared to standard models, contributing to greener living solutions. The incorporation of efficient compressors and high SEER (Seasonal Energy Efficiency Ratio) ratings ensures that users save money on their electricity bills while enjoying optimal cooling performance.

The units also feature advanced inverter technology, which allows for variable speed operation. This means that the system can adjust its cooling capacity based on the current temperature needs, resulting in more consistent comfort while reducing wear and tear on the equipment. Additionally, the inverter technology operates more quietly compared to traditional systems, making these models suitable for both home environments and commercial settings.

Friedrich 2008 and 2009 also provide users with enhanced control options. The inclusion of smart technology and Wi-Fi connectivity allows for remote monitoring and temperature adjustments via smartphones or tablets. Users can create schedules, set temperature preferences, and receive maintenance alerts, contributing to a more user-friendly experience.

Moreover, these models are designed with robust construction, featuring durable materials that withstand various weather conditions. Their compact footprint and sleek design make them suitable for window installation, while an array of sizes accommodates spaces of different dimensions.

Additionally, the air filtration systems in Friedrich 2008 and 2009 units improve indoor air quality. They effectively capture dust, allergens, and other particulates, ensuring a healthier environment for occupants.

In summary, Friedrich 2008 and 2009 models stand out for their energy efficiency, innovative inverter technology, smart controls, and robust construction. With a focus on user comfort and environmental responsibility, these models provide reliable solutions for effective heating and cooling in diverse applications.