How to use the remote control* (QuietMaster Programmable)

To start unit

1POWER - Press the Power button once. The unit will automatically turn on in the mode and fan speed it was last left on.

To set mode of operation

2COOL - Press the Cool button to automatically switch the operating mode to COOL.

3FAN ONLY - Press the Fan Only button if you want to run the fan only. You may want to use this feature in conjunction with the Fresh Air/ Exhaust if you want to bring outside air into the room, or exhaust stale air.

4MoneySaver® - Press the MoneySaver® button to activate the MoneySaver® feature. This cycles the fan with the compressor so that the fan does not run all the time.

To set the timer

NOTE: Set the hour clock before attempting to set timer functions. You can set the timer On/Off a minimum of one hour apart, and a maximum of 23 hours apart.

9TIMER START - Press Start to view the current start time for cool- ing. Continue pressing the Start button until you arrive at the start time you desire. The start time for cooling will then be set.

10TIMER STOP - Press the Stop button. Continue pressing the Stop button until you arrive at the stop time you desire. The stop time for cooling will then be set.

11TIMER ON/OFF - Press the On/off button once to activate (light on) or deactivate (light off) the timer. Once the Start and Stop times have been selected, they will remain in memory, and cycle daily until changed.

To adjust temperature

5COOLER - Press the Cooler button to raise the temperature setting.

6WARMER - Press the Warmer button to lower the temperature setting.

To adjust fan speed

7FAN SPEED - Press the Fan Speed button to see the current set- ting. Press again to change the fan speed. F1 is the lowest setting (SLEEP SETTING), F2 is low speed (LOW), F3 is medium (MED), and F4 is high (HIGH).

To set the hour clock

8SET HOUR CLOCK - Press Set Hour once to see the current clock set- ting. Continue pressing the button until you arrive at the current time.

MAKE SURE YOU SET THE A.M. AND P.M. PROPERLY. (NOTE: MINUTES ARE NOT SHOWN ON THE DISPLAY.) A light will appear in the upper left corner of the display when the hour is P.M.

*A Friedrich RC1 wireless remote control can be used to operate all QuietMaster® Programmable models.

NOTE: If the unit is unplugged or the power is interrupted, the HOUR CLOCK must be reset or the Timer On/off functions will not work.

Figure 4

 

 

 

 

 

 

Temperature

 

 

 

6

Cooler

 

Warmer

5

 

 

 

 

2

Cool

 

 

Power

1

 

 

 

 

 

 

 

3

Fan

Fan

 

Money

4

Only

Speed

Saver®

 

 

 

Timer Operation

 

 

7

11

On/O￿

Start

Stop

Set Hr.

8

 

 

 

 

9

 

 

 

 

10

13

Image 15
Contents Room Air Conditioners Technical Support Contact Information Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards Typical Unit Components Introduction6th Digit Voltage 1 = 115 Volts 1st Digit Function2nd Digit 7th Digit Options 0 = Straight Cool & Heat Pump ModelsChassis Specifications for 2009, 2008 models Installation information / sleeve dimensions Performance Data for 2009, 2008 models Fire Hazard Electric Shock HazardMake sure the wiring is adequate for your unit To start unit To adjust temperature 60F 16C to 90F 32CHow to use the remote control* QuietMaster Programmable How to operate the Friedrich room air conditioner XQ models How to use the remote control XQ models How to operate the Friedrich room air conditioner Testing the Electronic Control Boards for QME & XQ Models Checking Room TemperatureActivating Test Mode Testing the Electronic Control Error Code Listings KS, KM, SL Models See Figure Testing the Rotary Control SwitchesElectrical Components EQ08 System Control Switch TestFunctional Component Definitions Mechanical ComponentsThermostat Bulb Location Components TestingThermostat Adjustment TestResistor Heat Anticipator See Figure Defrost Thermostat Heat Pump Models OnlyDefrost Bulb Location Heat Pump Models FAN Motor CapacitorsCapacitor Check with Capacitor Analyzer Capacitor ConnectionsDrain PAN Valve Testing the Heating Element Electric Shock HazardHeating Element See Figure Heating Element Heat Pump ModelsSmart FAN Operating Sequence / Characteristics and FeaturesRefrigeration Sequence of Operation Risk of Electric Shock Sealed Refrigeration System RepairsEquipment Required Equipment Must be CapableMethod Of Charging / Repairs Burn HazardFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Capillary Tube Systems Hermetic Components CheckMetering Device Check ValveReversing Valve DESCRIPTION/OPERATION Checking the Reversing Valve Testing the CoilProcedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleExplosion Hazard Compressor Checks Single Phase Resistance Test Ground TestChecking Compressor Efficiency Compressor Replacement Recommended procedure for compressor replacementHigh Temperatures Rotary Compressor Special Troubleshooting and Service AIR Filter Routine MaintenanceCoils and Base PAN Excessive Weight Hazard Blower Wheel / Housing / Condenser FAN / ShroudFront Cover Sleeve / DrainProblem Possible Cause Action Cooling only Room AIR Conditioners Troubleshooting TipsReplace fuse, reset breaker. If repeats, check Fused separately Problem Possible Cause Action Heat / Cool only Room AIR Conditioners Troubleshooting Tips Problem Possible Cause Action Heat / Cool Room AIR Conditioners Trouble Shooting TipsSystem Cools When Heating is Desired Heat PumpYES Malfunction of Valve Normal Function of ValveElectronic Control Cool only Models Electronic Control Cool only Models Electromechanical Control Cool only Models SL28L30-D,-E SL36L30A-D,A-E Page Electromechanical Control Cool with Electric Heat Models EL36L35A-D,A-E Electromechanical Control Heat Pump only Models YS13L33-D,-E YM18L34-D,-E YL24L35-E,-F Aham PUB. NO. RAC-1 Cooling Load Estimate Form Heat Gain from Quantity FactorsDAY Heat Load Form Following is an example using the heat load formInfiltration Windows & Doors AVG Windows & Doors Area, sq. ftRoom AIR Conditioners Limited Warranty Page Technical Support Contact Information Friedrich AIR Conditioning CO
Related manuals
Manual 60 pages 54.38 Kb Manual 60 pages 45.7 Kb

2009, 2008 specifications

Friedrich 2008 and 2009 represent significant advancements in heating and cooling technology, particularly in the realm of air conditioning systems. Friedrich is known for producing robust and efficient HVAC solutions tailored for both residential and commercial applications. These models are particularly noteworthy for their innovative features and energy-efficient technologies that enhance user comfort and lower operational costs.

One of the main characteristics of the Friedrich 2008 and 2009 models is their emphasis on energy efficiency. Both units are designed to meet or exceed Energy Star standards, which indicates that they use less energy compared to standard models, contributing to greener living solutions. The incorporation of efficient compressors and high SEER (Seasonal Energy Efficiency Ratio) ratings ensures that users save money on their electricity bills while enjoying optimal cooling performance.

The units also feature advanced inverter technology, which allows for variable speed operation. This means that the system can adjust its cooling capacity based on the current temperature needs, resulting in more consistent comfort while reducing wear and tear on the equipment. Additionally, the inverter technology operates more quietly compared to traditional systems, making these models suitable for both home environments and commercial settings.

Friedrich 2008 and 2009 also provide users with enhanced control options. The inclusion of smart technology and Wi-Fi connectivity allows for remote monitoring and temperature adjustments via smartphones or tablets. Users can create schedules, set temperature preferences, and receive maintenance alerts, contributing to a more user-friendly experience.

Moreover, these models are designed with robust construction, featuring durable materials that withstand various weather conditions. Their compact footprint and sleek design make them suitable for window installation, while an array of sizes accommodates spaces of different dimensions.

Additionally, the air filtration systems in Friedrich 2008 and 2009 units improve indoor air quality. They effectively capture dust, allergens, and other particulates, ensuring a healthier environment for occupants.

In summary, Friedrich 2008 and 2009 models stand out for their energy efficiency, innovative inverter technology, smart controls, and robust construction. With a focus on user comfort and environmental responsibility, these models provide reliable solutions for effective heating and cooling in diverse applications.