Emerson operation manual Copeland CoreSense E2 Alarms, ISD 2.0/2.1 CoreSense Diagnostics

Models: E2

1 283
Download 283 pages 10.27 Kb
Page 241
Image 241

Copeland CoreSense E2 Alarms

 

E2

 

 

 

E2 Advisory Text

Advisory

E2 Display Code Text

E2 Associated Alarm

CoreSense Device

(Advisory Log)

Priority

Property

Display (LCD)

 

(default)

 

 

 

 

 

 

 

 

 

 

ISD 2.0/2.1 CoreSense Diagnostics

 

LCD Failure

99

LCD Failure

LCD FAILURE

“Control Module

 

 

 

 

EEPROM Failed”

Fault Discharge Temp Sens

99

Off-Fault Disch Temp

DISCH TEMP OPN

“Normal OFF

 

 

 

 

Fault Temp Probe”

Unld2 Sol Open Circuit

99

Off-Unloader 2 Open

UNLD2 OPN WARN

“Normal OFF

 

 

 

 

Unloader2 Open”

Unld1 Sol Open Circuit

99

Off-Unloader 1 Open

UNLD1 OPN WARN

“Normal OFF

 

 

 

 

Unloader1 Open”

Unld2 Sol Short Circuit

99

Off-Unloader 2 Short

UNLD2 SC WARN

“Normal OFF

 

 

 

 

Unloader2 Short

Unld1 Sol Short Circuit

99

Off-Unloader 1 Short

UNLD1 SC WARN

Normal OFF

 

 

 

 

Unloader1 Short

Fault Discharge Temp Sens

99

Run-Fault Disch Temp

DISCH TEMP OPN

Normal Running Fault

 

 

 

 

Temp Probe

Unld2 Sol Open Circuit

99

Run-Unloader 2 Open

UNLD2 OPN WARN

Normal Running

 

 

 

 

Unloader2 Open

Unld1 Sol Open Circuit

99

Run-Unloader 1 Open

UNLD1 OPN WARN

Normal Running

 

 

 

 

Unloader1 Open

Unld2 Sol Short Circuit

99

Run-Unloader 2 Short

UNLD2 SC WARN

Normal Running

 

 

 

 

Unloader2 Short

Unld1 Sol Short Circuit

99

Run-Unloader 1 Short

UNLD1 SC WARN

Normal Running

 

 

 

 

Unloader1 Short

No Comm Sensor to CT

20

Comm Loss Sensor - CT

NO COMM CT

Connection Lost

 

 

 

 

CT To Sensor

Low Oil Warning

99

Run-Low Oil Prs Warn

LOW OIL WARN

Normal Running

 

 

 

 

Low Oil Pressure

No Comm Sensor to ID

20

Comm Loss Sensor - ID

NO COMM ID

Connection Lost ID To

 

 

 

 

Sensor

Comp ID Module Failure

20

Comp ID Module Fail

COMP ID FAIL

Compressor ID Mod-

 

 

 

 

ule Failed

No Comm Sensor Modul

20

Comm Loss Sensor Mod

NO COMM SENSOR

No Communication To

 

 

 

 

Sensor Module

Sensor Module Failure

20

Sensor Module Fail

SENS MOD FAIL

Sensor Module Failure

 

 

 

 

 

Device Absent

20

No Communications E2

NO COMM E2

No Communication

 

 

 

 

 

Discharge Temp Trip

20

Disch Temp Trip

DISCH TEMP TRIP

Discharge Temp Trip

 

 

 

 

 

Brown Out Trip

20

Comp Brown Out Trip

BROWN OUT TRIP

Power BrownOut Trip

 

 

 

 

 

Compressor Low Volt Trip

20

Comp Low Voltage Trip

LOW VLT TRIP

Compressor Low Volt-

 

 

 

 

age Trip

Supply Voltage Trip

20

Comp Mod Supply V Trp

SUPPLY VLT TRIP

Module Low Voltage

 

 

 

 

Trip

Part Winding Trip

20

Part Winding Trip

PART WIND TRIP

Part Winding Trip

 

 

 

 

 

Voltage Imbalance

20

Voltage Imbalance

VOLT IMBALANCE

Vol Imbalance Trip

 

 

 

 

 

Copeland CoreSense E2 Alarms C-15

Page 241
Image 241
Emerson operation manual Copeland CoreSense E2 Alarms, ISD 2.0/2.1 CoreSense Diagnostics