12 Operator’s Guide to Using the E2

12.1 The E2 Home Screen

Circuit Status Section

 

 

 

The Main Status or Home screen (Figure 12-1and

To the right of the Suction Groups section is the Circuit

Status section. Both the Standard Circuits and the Case

Figure 12-2) is divided into sections that display the cur-

Controllers are listed in this screen. The circuit names,

rent status in areas of importance in the system (i.e., for

their current status, and temperatures are listed.

RX: suction groups, compressor stages active, circuits,

Condenser Section

 

condensers, sensor control, and for BX: OAT, demand

 

This section is located at the bottom left of the screen

control, power monitoring, light schedules, zones, AHUs,

and contains information on the status of the condenser,

and sensor control). Time, date, and alarm status are dis-

such as the discharge setpoint and individual fan states.

played along the top of the screen. The display is backlit,

Sensor Control

 

but turns off to save energy after a determined amount of

 

time. Press any key to bring the display back up.

Below the Circuits section at the bottom right of the

The Home screen acts as a master and default screen

screen is the Sensor Control section where Control Value

for all the functions of E2 and can be customized accord-

and Command information are displayed.

ing to the user’s needs (see Section 12.5, Customizing the

12.1.2 BX Home Screen

Home Screen).

 

 

The RX Home screen can be displayed on CX model

 

 

controllers.

 

 

 

 

12.1.1 RX Home Screen

14

13

 

 

 

 

12

1

7

 

 

11

 

8

6

 

 

 

 

 

 

 

7

8

9

10

 

 

1 Outside Humidity

8 Sensor Control

 

 

9

2 Outside Air Temperature

9 Zones

 

 

 

3 Season

10 Controller Information

 

7

Advisory Information

4 Light Level (FTC)

11 Network Information

 

5 Demand Control

12 Advisory Information

 

8

Network Information

6 Power Monitoring

13 Air Handling Units

 

9

Controller Information

 

7 Function Button Index (5) 14 Light Schedules

 

 

 

 

Figure 12-1- RX Home Screen

Figure 12-2- BX Home Screen

 

 

 

Suction Groups Section

The first section of the RX Home screen is the Suction Groups section located in the top left corner. The large let- ters have the name of Suction Group 1 along with infor- mation on compressor stages active, and the current pressure setpoint. Setpoints, status, percentages of capaci- ties, and which stages are active for each suction group are displayed as well. The suction group that is displayed in the large block at the top left of the screen is the group that is named alphabetically first of the suction groups.

OAT Section

The upper-left hand section of the BX Home screen contains status information for four different values, including outside air temperature, humidity percentage, season, and light level.

Demand Control Section

Directly below the OAT section is demand control sta- tus information, which shows the number of applications and number of loads being shed.

The E2 Home Screen

Operator’s Guide to Using the E2 12-1