Figure 12-10- Status Screen (RX-400 Version Shown)

Setup Screens

The Setup utility is the interface used to change set- tings and setpoints, and define inputs and outputs in the E2. Figure 10-11shows a typical Setup screen and its pri- mary elements.

Index Tabs:

The screen may require one or more fields to be set to certain values before the screen may be accessed. For example, a screen containing nothing but com- pressor proof input definitions might be hidden if there is a field on another screen that tells the sys- tem there are no proof checking devices on the group’s compressors. To access this screen, you would have to set this field to YES.

The screen you are currently in is always highlighted in the screen’s index tab. For example, because Screen 1 is displayed, tab C1 is highlighted.

As you move to other screens within Setup, the high- light will move to different tabs to indicate which screen will be displayed.

Header Icons:

Figure 12-12- Header Icons

At the very top of every screen in the E2, there are icons that indicate various stages of activity, number of users logged into the controller, battery alerts, connectivity status, and more.

Figure 12-11- Index Tabs (RX-400 Version Shown)

The 10 boxes at the top of the screen labeled C1 through C0 are known as the index tabs. These tabs pro- vide you with a short index of the screens that are used to set up an application. C1 through C0 represent the screen numbers (C1 being screen 1, C2 being screen 2, and so

on.) Press the key and the number of the index tab (next to the C) and the cursor highlights that index tab.

Each of the Setup screens that you may access will have a name beside its number. In Figure 10-11, for exam- ple, you will notice some tabs have names, while others are blank. This is because there are only four screens in the Setup for this particular application; C3 is not an accessi- ble screen.

There are several reasons why a tab may be inaccessi- ble (i.e., without a name next to the number):

The tab (and the corresponding screen) is unused and reserved for later revisions.

The screen may only be accessed when running in Full Options mode (see Section 12.2, Logging On and Access Levels).

Icon

Description

 

 

 

Single user is logged in

 

 

 

Multi-users are logged in

 

 

 

Terminal mode in use

 

 

 

E2 is connected to Ethernet

 

 

 

Wait, or system is busy

Disk activity, or saving to disk

Caps lock is ON

Table 12-4- Header Icons and Descriptions