Craftsman 919.72412 owner manual Risk of Burns, Risk from Moving Parts, Risk of Falling

Page 7

HAZARD

RISK OF BURNS

WHAT CAN HAPPEN

TOUCHING EXPOSED METAL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES,

CAN RESULT IN SERIOUS BURNS.

HOW TO PREVENT IT

NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRESSOR DURING OR IMMEDIATELY AFTER OPERATION. COMPRESSOR WILL REMAIN HOT FOR SEVERAL MINUTES AFTER OPERATION.

DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE

UNTIL UNIT HAS BEEN ALLOWED TO COOL.

HAZARD

RISK FROM MOVING PARTS

WHAT CAN HAPPEN

MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING.

ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGED OR MISSING PARTS OR ATTEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN

RESULT IN SERIOUS INJURY.

HOW TO PREVENT IT

NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAMAGED

OR REMOVED.

ANY REPAIRS REQUIRED ON THIS PRODUCT

SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL.

HAZARD

RISK OF FALLING

WHAT CAN HAPPEN

A PORTABLE COMPRESSOR CAN FALL FROM A TABLE, WORKBENCH OR ROOF CAUSING

DAMAGE TO THE COMPRESSOR AND COULD RESULT IN SERIOUS INJURY OR DEATH TO THE OPERATOR.

HOW TO PREVENT IT

ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE POSITION TO PREVENT ACCIDENTAL MOVEMENT OF THE UNIT. NEVER

OPERATE COMPRESSOR ON A ROOF OR

OTHER ELEVATED POSITION. USE ADDITIONAL AIR HOSE TO REACH HIGH LOCATIONS.

7- ENG

D24461

Image 7
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorWarranty Table of ContentsSafety Guidelines Definitions Specification ChartImportant Safety Instructions Risk of Explosion or Fire HazardRisk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk from Moving Parts Risk of BurnsRisk of Falling Risk of Unsafe Operation Duty Cycle AccessoriesAccessories GlossaryInstalling Handles Wheels, and Molded Foot Bumpers AssemblyContents of Carton Tools Required for AssemblyImproper Grounding can Result in Electrical Shock InstallationLocation of the Air Compressor Risk of ElectricalVoltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation Check Valve How to StopBefore Starting Drain ValveBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Check ValveTo Replace Regulator StorageRegulator Arrow Problem Cause Correction TroubleshootingPressure reading Problem Cause Correction Garantie Complète DE UN AN SUR LES Compresseurs D’AIR Pour Placer UNE Commande DE PiècesMesures DE Sécurité Définitions Tableau DES SpécificationsConsignes DE Sécurité Importantes Risque Risque D’EXPLOSION OU D’INCENDIERisque DE Projection D’OBJETS Risque D’ÉCLATEMENTRisque PAR Inhalation Risque DE Choc ÉlectriqueRisque Relié AUX Pièces Mobiles Risque DE BrûluresRisque DE Chute Risque Dune Utilisation Dangereuse Lexique AccessoiresCycle DE Service AccessoiresBoulon à épaulement AssemblageContenu de la boîte Outils requis pourlassemblageDirectives DE Mise À LA Terre Emplacement du compresseur dairProtection contre la surtension et Protection du circuit RallongesInterrupteur On/Auto/OffManostat UtilisationFamiliarisez-vous avec votre compresseur dair Description du fonctionnementArrêt de lappareil Utilisation de lappareilAvant le démarrage Mise en marche Avant chaque mise en marcheVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéTournevis Remplacement ou nettoyage de la soupape de retenueEntretien ET Réglages Tube de sortie ÉcrouRangement Remplacement du régulateurRégulateur Flèche Peut éclater ou exploser DépannageProblème Cause Correction SerrerConsidérée normale Fusible sauté ou coupe-circuit Remarque 51- FR D24461 Get it fixed, at your home or ours