Craftsman 919.72412 owner manual Installation, Location of the Air Compressor, Risk of Electrical

Page 11

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

Plug

Grounded

Outlets

Grounding Pin

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL

SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

IMPROPER GROUNDING CAN

RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

11- ENG

D24461

Image 11
Contents Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8 AIR CompressorWarranty Table of ContentsImportant Safety Instructions Specification ChartSafety Guidelines Definitions Risk of Explosion or Fire HazardRisk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk of Falling Risk of BurnsRisk from Moving Parts Risk of Unsafe Operation Duty Cycle AccessoriesAccessories GlossaryInstalling Handles Wheels, and Molded Foot Bumpers AssemblyContents of Carton Tools Required for AssemblyImproper Grounding can Result in Electrical Shock InstallationLocation of the Air Compressor Risk of ElectricalVoltage and Circuit Protection Extension CordsDescription of Operation OperationKnow Your Air Compressor Check Valve How to StopBefore Starting Drain ValveBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Check ValveRegulator Arrow StorageTo Replace Regulator Problem Cause Correction TroubleshootingPressure reading Problem Cause Correction Garantie Complète DE UN AN SUR LES Compresseurs D’AIR Pour Placer UNE Commande DE PiècesConsignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Risque Risque D’EXPLOSION OU D’INCENDIERisque DE Projection D’OBJETS Risque D’ÉCLATEMENTRisque PAR Inhalation Risque DE Choc ÉlectriqueRisque DE Chute Risque DE BrûluresRisque Relié AUX Pièces Mobiles Risque Dune Utilisation Dangereuse Lexique AccessoiresCycle DE Service AccessoiresBoulon à épaulement AssemblageContenu de la boîte Outils requis pourlassemblageDirectives DE Mise À LA Terre Emplacement du compresseur dairProtection contre la surtension et Protection du circuit RallongesInterrupteur On/Auto/OffManostat UtilisationFamiliarisez-vous avec votre compresseur dair Description du fonctionnementAvant le démarrage Utilisation de lappareilArrêt de lappareil Mise en marche Avant chaque mise en marcheVidange du réservoir EntretienResponsabilités du client Vérification de la soupape de sûretéTournevis Remplacement ou nettoyage de la soupape de retenueEntretien ET Réglages Tube de sortie ÉcrouRégulateur Flèche Remplacement du régulateurRangement Peut éclater ou exploser DépannageProblème Cause Correction SerrerConsidérée normale Fusible sauté ou coupe-circuit Remarque 51- FR D24461 Get it fixed, at your home or ours