Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.
Drain
Valve
Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes in large amounts. You know that the cooling system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches
Check Valve
How to Use Your Unit
How to Stop:
1.Set the On/Auto/Off lever to "OFF".
Before Starting
Break-in Procedure
Serious damage may result if the
following
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
1.Make sure the On/Auto/Off lever is in the "OFF" position.
NOTE: Pull coupler back until it clicks to prevent air from escaping through the quick connect.
2.Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.)
3.Open the drain valve fully
4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.
5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure
6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to
The compressor is now ready for use.
D24461 | 14- ENG |